  • Page 2: Table Of Contents

    2.0 Kit Contents ............................3 3.0 Dielectric Main Cable Preparation (No Ground) ................5 4.0 Armored Main Cable Preparation .......................5 5.0 3 M 20 mm Double ECAM (External Cable Assembly Module) ™ Cable Assembly Removal and Installation ..................6 6.0 Fiber Slack Storage ..........................6 7.0 Ribbon: Port Assignments........................7 8.0 SC External (HFOC) Adapter Installation Ports 1, 2, 3, 4, 5 and 8 ............7 9.0 3M SC External Adapter Port Expander Kit Installation for Ports 6 and 7 ........9 ™ 10.0 SC Pigtail Installation and Splicing ....................9 11.0 Cable Splicing ...........................10 12.0 Closure Sealing ..........................13 13.0 Accessories ............................15 78-8135-6695-3-C...
  • Page 3: Introduction

    ™ Termination can accommodate up to eight external drops, two .79” (20 mm) main cables. The FDTC 08S closure accommodates both dielectric and armored main cables using a grounding kit that must be purchased separately. Specifications Item Qty. Description SC External Adapters 4, 6 (requires 3M External Cable Assembly Module (ECAM) Port Expander) ™ Tray Capacity: Fiber Optic Splice Trays 2538 ™ Splice Tray Capacity: Single Fusion (Double Stacked) Mass Fusion Fibrlok Splices ™...
  • Page 4 External adapter (HFOC) D ouble External Cable Assembly Module ™ (ECAM) Port, top and bottom halves assembly Double ECAM loose parts Fiber Optic Splice Tray 2538 ™ Band 78-8135-6695-3-B Instructions FDTC 08S 78-8140-3820-0 Instructions ECAM-20MM-D Fiber Optic Splice Tray 2538 ™ Splice tray Tray cover (2) 3M Single Fusion Spice Holder 2521-F ™ (1) 3M Ribbon Spice Holder 2521-FL ™ Label Cable ties Rubber gripper Double External Cable Assembly Module ™ (ECAM) Port Loose Parts Cable Washers Mastic Roll Top & Bottom Halves...
  • Page 5: Dielectric Main Cable Preparation (No Ground)

    3.0 Dielectric Main Cable Preparation (No Ground) EXPRESS LOOSE BUFFER TUBE CABLE 6”(150mm) 3”(75mm) TRIM SINGLE OR SCUFF SHEATH DUAL CSM RODS ON ALL CABLES TYPICAL CABLE PREP 72” MAX (1.8m) SHEATH REMOVED EXPRESS CENTRAL TUBE CABLE 6”(150mm) 8”(200mm) TRIM SINGLE OR CENTRAL TUBE DUAL CSM RODS TYPICAL CABLE PREP 72”...
  • Page 6: Cable Assembly Removal And Installation

    Internal Ground ™ Kit 14 AWG Kit 6 AWG 4.2 Wrap sheath and ground terminal with tape to protect fibers from sharp edges. Grounding Kits must be purchased separately: ™ ECAM-GND-6-AWG 80-6113-1702-7 ECAM-GND-14-AWG 80-6113-1704-3 5.0 3M 20 mm Double External Cable Assembly Module (ECAM) ™ Cable Assembly Removal and Installation 5.1 Please refer to instructions 78-8140-3820-0 Double External Cable Assembly Module ECAM-20MM-D (included in kit) for cable seal preparation. 6.0 Fiber Slack Storage 6.1 Determine buffer tube or ribbon to be cut and cut at appropriate end for splicing. 6.2 Store remaining express fiber slack as shown. Do not exceed minimum bend radius. Loose Buffer Tube...
  • Page 7: Ribbon: Port Assignments

    Ribbon 6.3 Using tie wraps secure the central tube in the storage tray as shown. 7.0 Ribbon: Port Assignments 7.1 Drop port locations are numbered 1–8. SC External SC External Adapter Adapter Port No. (HFOC) Port No. (HFOC) (Port 1-4) Blank Blank Blank Blank Adapter Adapter Adapter Adapter 12 mm 12 mm ™ ™ 12 mm 12 mm ™ ™ ECAM Port ECAM Port ECAM Port ECAM Port 8.0 SC External (HFOC) Adapter Installation Ports 1, 2, 3, 4, 5 and 8 8.1 Clean blank port plug. Remove port plug screw inside base as shown.
  • Page 8 8.2 Then remove both inner and outer port plug halves. Keep the O-ring. Remove retaining nut, washer and O-ring from external adapter. 8.3 Compare this o-ring to the O-ring supplied with the SC external adapter. Note: Do not use the thinner O-ring! If necessary reuse the port plug O-ring. 8.4 Install the lightly lubricated O-ring onto external adapter. Note: Follow health, safety and environmental information, refer to product label or Material Safety Data Sheet for Silicone Lubricant. 8.5 Make sure port is clear of dirt. Insert into base by aligning the keying features on both parts. 78-8135-6695-3-C...
  • Page 9: Sc External Adapter Port Expander Kit Installation For Ports 6 And 7

    8.6 Install SC external adapter’s washer and nut inside closure to retain the external adapter. Install retaining nut with the grooves facing out. Note: The installation tool mates with these grooves. 8.7 Using the installation tool and can wrench, tighten retaining nut to 20 in.-lbs. ± 5 in.-lbs. 9.0 3M SC External Adapter Port Expander Kit Installation for ™ Ports 6 and 7 9.1 SC external adapter can be added to ports 6 and 7 by using a port expander kit. Install per instructions supplied with the kit. Note: Ports 6 and 7 can be used as branch ports for cables up to 0.48” (12 mm) in diameter. Use 3M 12 mm ™ External Cable Assembly Module (ECAM) Kits to add cables to these ports. 10.0 SC Pigtail Installation and Splicing 10.1 Clean SC pigtail connector ends per company procedure. 10.2 Install SC pigtails into SC external adapters by first removing caps on both the pigtails and adapter. 78-8135-6695-3-C...
  • Page 10: Cable Splicing

    10.3 Note the location of the key on the SC connector and adapter. Mate the SC with key feature facing the rear of the closure. 11.0 Cable Splicing 11.1 Determine type of splice insert needed. 3 mm Discrete Fusion Tray 2521-F ™ diameter fusion sleeves (3M Fusion Sleeves 2170) ™ are recommended. Smaller diameter sleeves may require the use of RTV to aid in retention. Mass Fusion 2521-FL and 3M Fibrlok Splices ™ ™ ™ 11.2 Install splice insert into splice tray by slipping tabs under metal retainers as shown. 11.3 Attach splice log decal to cover. Note: Bottom portion of decal can be cut off and used to identify individual trays. 78-8135-6695-3-C...
  • Page 11 11.4 Place splice tray in storage tray. Tabs on tray nest between tabs in storage tray. 11.5 If needed tray can be held in storage tray by using a tie wrap as shown. Loose Buffer Tube 11.6 Fiber slack can be store in tray as shown. 11.7 Buffer tube splicing can be done with the splice tray removed from the storage tray, as shown. 78-8135-6695-3-C...
  • Page 12 11.8 Route fiber into tray to determine the amount of buffer tube to remove. Remove buffer tube and clean fiber as required. 11.9 Cut a 1” (25 mm) long section of the rubber gripper supplied with the splice tray kit and use to secure buffer tubes or ribbon fiber (up to six) to tray. 11.10 Group up to four pigtails per rubber gripper to be spliced and route and install in tray. 11.11 Splicing can be done with the splice tray mounted inside the storage tray (recommended for ribbon splicing) or can be removed. 78-8135-6695-3-C...
  • Page 13: Closure Sealing

    Ribbon 11.12 Mount ribbon fanout on backside of the splice tray and secure with cable tie. Plug SC connector end into HFOC adaptors as shown. 11.13 Recommend ribbon splicing be done with the splice tray mounted inside the storage tray. 11.14 Replace cover and secure tray(s) by reattaching retaining strap. 12.0 Closure Sealing 12.1 Ensure both the dome seal area and base O-ring is free of dirt or any damage. If needed clean area and apply a light film of supplied silicone lubricant. Failure to maintain a clean seal area may lead to leakage. Note: Follow health, safety and environmental information, refer to product label or Material Safety Data Sheet for Silicone Lubricant. 78-8135-6695-3-C...
  • Page 14 12.2 Clean and lubricate O-ring. 12.3 Replace dome and engage latch over dome ear as shown. 12.4 Fully close latch to seat dome onto the base. 12.5 Assembled unit can be flash tested at 5.8 PSI (40kPa) MAX.  Caution Vent pressure after flash testing. 78-8135-6695-3-C...
  • Page 15: Accessories

    12.6 External grounding can be added to ground lug on base. 13.0 3M Fiber Dome Terminal Closure FDTC 08S Accessories ™ UPC Number 3M I.D. Number Description 00051115191909 80611316961 ECAM-12MM 12MM ECAM CABLE ENTRY PORT 00051115191961 80611317027 ECAM-GND-6-AWG ECAM (18, 20, 27MM) CABLE GND (6 AWG) 00051115191985 80611317043 ECAM-GND-14-AWG ECAM CABLE GND (14 AWG) 00051115192005...
  • Page 16 Warranty; Limited Remedy; Limited Liability. This product will be free from defects in material and manufacture for a period of one (1) year from the time of purchase. 3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

Table of Contents