CONNECTING
ELECTRIC DRYERS (continued)
,A WARNING:
Connect the power cord to the terminal
block. Connect
each power cord wire to the fermlnal
block screw that
has the same colored wire. For example, connect the
black power cord wire to the fermlnal
block screw
with the black wire. Failure to follow these instructions
may result in a short, overload,
fire or death.
Four-Wire
Power
Cord
* A 4-wlre connection is required for all
moblle and manufactured
home installations,
as well as all new construction after
January 1, 1996.
* A UL-listed strain relief is required.
* Use a 30-amp, 240-volt,
4-wire,
UHisted
power cord
with #10 AWG-mlnlmum
copper conductor and closed
loop or forked terminals with upturned ends.
Terminal
Block
UL-Listed
Relief
UL-Listed
_
4 Wire
Power
Cord
O
Remove the terminal
block
access
cover
on the upper
back
of the dryer.
Install
a UL-tisted
strain
relief
into the power
cord
through-hole.
Thread
a 30-amp,
240-volt,
4-wire,
UL-listed
power
cord
with
#10 AWG-minimum
copper
conductor
through
the strain
relief.
_:__
Hot
::..... ;::::_:::: _
Hot
_Neutral
(Black)
Green Ground
Neutral
Green Wire
Grounding
Power Cord
Wire
Transfer the neutral grounding wire from behind the
green ground screw to the center screw of the terminal
block.
Attach the two hot leads (black and red) of the power
cord to the outer terminal block screws.
Attach the power cord white neutral wire to the cen-
ter screw of the terminal block.
Attach the power cord ground wire to the green
ground screw.
TIGHTEN ALL SCREWS SECURELY.
Reinstall the terminal block access cover.
Grounding through the neutral wire is prohibited for: (1)
new branch-clrcult installatlons, (2) moblle homes, (3)
recreational
vehicles, and (4) areas where local codes
prohibit grounding through
the neutral wire.
Three-Wire
Power Cord
* A 3-wlre connection is NOT permitted on
new construction after January 1, 1996.
" A UL-listed strain relief is required.
* Use a 30-amp,
240-volt,
3-wire,
UL-tisted
power
cord
with
#10 AWG-minimum
copper
conductor
and closed
loop
or forked
terminals
with
upturned
ends.
Terminal
)_
Block
%:- __
I, I II
UL-Listed
-
_-!1
__
3Wire
i I!!
\\co,a
Remove the terminal block accesscover onthe upper
back of the dryer.
install a UL-tisted strain relief into the power cord
through-hole.
t_
Thread a 30-amp,
240-volt,
3-wire, UL-listed power
cord with #10 AWG-minimum
copper conductor
through the strain relief.
Neutral
-_:__
Grounding
............. -........_
Hot
......
_., ........
r10T
lNeuTral
,_.,
Green G-I:
_
.....
_ J
External Ground
Wire _
_-'_"-_'_
Attach the two hot leads (black and red) of the
power cord to the outer terminal
block screws.
@
@
@
@
Attach the power cord neutral (white) wire to the center
terminal block screw.
Connect the external ground (if required by local
codes) to the green ground screw.
TIGHTEN ALL SCREWS SECURELY.
Reinstall the terminal
block access coven
13