Filling The Water Heater; Wiring Diagram; Wiring - Sears 153.313230 Owner's Manual

Table of Contents

Advertisement

Filling the Water Heater
To fill the water heater with water:
1. Close the water heater drain valve by turning
the han-
dle to the right (clockwise).
The drain valve is on the
lower front of the water heater.
2. Open the cold water supply valve to the water heater.
NOTE: The cold water supply valve must be left open
when the water heater is in use.
3. To insure complete
filling
of the tank, allow
air to exit
by opening
the nearest hot water faucet. Allow
water to
run until a constant
flow
is obtained.
This will
let air
out of the water heater and the piping.
CAUTION
Never use this water heater unless it is completely
filled with water. To prevent damage to the tank and
heating element,
the tank must be filled with water.
Water
must flow from the hot water faucet
before
turning "ON"
power.
4. Check all new water piping for leaks. Repair as needed.
Wiring Diagram
STANDARD
WIRING
FOR
2 WIRE LEAD WATER HEATERS
240 VOLT SINGLE ELEMENT
k3
<
TO ELECTRIC
POWER
SUPPLY
IK I
I 'UNcg'°N
BLAC
RED
LOWER
ATING
ELEMENT
Wiring
CAUTION
Never use this water heater unless it is completely full of
water. To prevent damage to the tank andheatlng
ele-
ment,
the tank must be filled
with water.
Water
must
flow from
the hot water
faucet
before
turning
"on"
power.
You must provide
all wiring
of the proper size outside
of
the water
heater. You must obey local codes and electric
company
requirements
when you install this wiring.
If you are not familiar
with electric codes and practices, or
if you have any doubt,
even the slightest doubt,
in your
ability
to connect
the wiring
to this water heater, obtain
the service of a competent
electrician.
Contact your Sears
salesperson
to arrange for a professional
electrician.
WARNING
WATER
HEATERS
EQUIPPED
FOR ONE
VOLTAGE
ONLY: This water heater is equipped for one type volt-
age only.
Check the rating
plate
near the bottom
access panel for the correct voltage. DO NOT use this
water
heater
with
any voltage
other than the one
shown on the model
rating plate. Failure to use the
correct
voltage can cause problems which can result
in death, serious bodily injury, or property
damage. If
you have any questions or doubts consult your electric
company.
CAUTION
If wiring from your fuse box or circuit breaker box was
aluminum for your old water heater, replace it with cop-
per wire.
If you wish to reuse the existing
aluminum
wire, have the connection at the water heater made by a
competent
electrician.
Contact your Sears salesperson to
arrange for a professional electrician.
1.
2.
Provide
a way to easily
shut off the electric
power
when working
on the water heater. This could
be with
a circuit
breaker or fuse block in the entrance box or a
separate disconnect
switch.
Install and connect
a circuit
directly
from the main fuse
or circuit
breaker
box. This circuit
must be the right
size and have its own fuse or circuit
breaker.
Refer to
the chart in the "Specifications"
section for the correct
size wire and fuse or circuit
breaker.
3. If metal conduit
is used for the grounding
conductor:
A. The grounding
electrode
conductor
shall be of cop-
per, aluminum,
or copperclad
aluminum.
The mate-
rial shall
be of one
continuous
length
without
a
splice or joint.
10