U
Safety Instructions ......... 2,s
Operating Instructions
..... 4-9
Air Filter ..........................
11
Front Grille ........................
10
Grille and Case ...................
10
Outdoor Coils ....................
10
Before You Begin ..............
12, 13
an Existing Wall Case .............
14
Through-the-Wall
Installation .......................
15
(Optional) ......................
16-21
Tips .......
22
22
Consumer Support
Consumer Support ......
Back Cover
Warranty .........................
23
*ENERGY
STAR ®
labeled product
ENERGY STAR
As an ENERGY STAR ® partner, GE has
determined that this product meets the
ENERGY STAR ® guidelines for energy efficiency.
Cool Only:
Heat/Cool:
AJCN 08, 10
ACD*
AJCN 10, 12
DCD*
AJCQ 06
LCD*
AJCQ 08, 10, 12
ACD*
AJCQ 09, 10, 12
DCD*
AJEM 12
DCD
AJEQ 06
LCD
AJEQ 08
ACD
AJEQ 09, 10, 12
DCD
Espafiol
For a Spanish version of this manual, visit
our Website at GEAppliances.com.
Para consultar una version en espaflol de
este manual de instrucciones, visite nuestro
sitio de internet GEAppliances.com.
Frangaise
For a French version of this
manual,
visit
our Website at GEAppliances.com.
Pour une version franqaise de ce manuel
d'utilisation, veuillez visiter notre site web
(_ I'adresse GEAppliances.com.
O_
Write the model and serial
numbers here:
Model #
Serial #
Find these numbers on a label on the front of
the base pan behind the front grille.
TINSEA568JBRZ
49-7597-4
03-11
GE

Advertisement

Table of Contents
loading

Summary of Contents for GE AJCM 08,10

  • Page 1: Table Of Contents

    Pour une version franqaise de ce manuel d'utilisation, veuillez visiter notre site web (_ I'adresse GEAppliances.com. ENERGY STAR As an ENERGY STAR ® partner, GE has determined that this product meets the ENERGY STAR ® guidelines for energy efficiency. Write the model and serial...
  • Page 2 IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING. SAFETYPRECAUTIONS WARNING! Risk of e lectric shock. new power supply cord obtained from the manufacturer and not repaired. Do Can cause injury or death. For your safety, not use a cord that shows crocks or the information in this manual must be followed...
  • Page 3 GEAppliances.com USE OF EXTENSION CORDS--115-volt models onl A WARNING! Risk ofelectric shock. DO NOT use an extension cord with any of the 230/208-volt models. Can cause injury or death. We strongly recommend against the use of an extension cord. If you must use an extension cord, it is absolutely necessary that it be u UL-listed, 14-gauge, 3-wire grounding- type appliance extension cord having u...
  • Page 4 About the controls on the air conditioner-Cool Only Models may vary. Appearance • COOL • • HIGH • • • TIMER TEMP Air Conditioner Controls Remote Control Lights beside the touch pods on the oir conditioner control ponel indicote the selected settings. Controls To cancel the On Timer, press the ON pad ON/OFF...
  • Page 5 GEAppliances.com COOL NODE RemoteControl Setthethermostatat a highernumberand the indoorair will becomewarmer. 1. PressCOOLpad. NOTE: I f the air conditionerisoff and isthenturnedon 2. PressLOW, NED or HIGH pads to set desired fan whileset to COOL, i t will take approximately 3 minutes speed.
  • Page 6 About the controls on the air conditioner-Heat/Cool Models Appearance may vary. ON/OFF • Cool • • HIGH • HEAT • OFF • Low TIMER TEMP Air Conditioner Controls Remote Control Lights beside the touch pads on the air conditioner control panel indicate the selected settings. Controls TIMER ON/OFF...
  • Page 7 GEAppliances.com COOL MODE RemoteControl Setthethermostatat a highernumberand the indoorair will becomewarmer. 1.Press COOL pad. NOTE: I f theair conditioner i s off and isthenturnedon 2.Press LOWor HIGHpadsto set desiredfan speed. whileset to COOL, it will takeapproximately 3 minutes for thecompressor t o start andcoolingto begin. 3.Press the INCREASE + / DECREASE - padsto setthe desiredtemperature50°Fto 85°Fin I°F increments.
  • Page 8 About the controls on the air conditioner Vent Control Thevent control islocatedbehindthe front grilleon the Theunit leavesthefactorysetat the CLOSE position. right sideofthe air discharge area.WhenCLOSED, only hole the air insidethe roomwill be circulatedand conditioned. WhenOPEN, the vent allowsoutdoorflesh air exchange. ocatinghole Toopenor closethe vent: 1.
  • Page 9: Care And Cleaning

    GEAppliances.com Terminal Connections Remote Thermostat - Class 2 (on some models) The controls are located under a plastic cover behind the front grille. -] emove the front grille.See the Front Grille connections Terminal section of Care and Cleaning. location Removethe screws securing the plastic cover underfront grille over the wiring connections.
  • Page 10: Front Grille

    Care and cleaning of the air conditioner. Grille and Case Turn the oir conditioner off ond remove the plug To cleon, use woter ond o mild detergent. from the woll outlet before cleoning. Do not use bleoch or obrosives. Outdoor Coils The coils on the outdoor side of the oir conditioner should be checked regulorly.
  • Page 11: Air Filter

    Replacement filters are available from your salesperson, GE dealer, GE Service and Parts Center or authorized Customer Care ® servicers. How to Insert the Batteries in the Remote Control...
  • Page 12: Installation Instructions

    Installation Air Conditioner Instructions 1"-#1 Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: GEAppliances.com BEFOREYOU BEGIN ELECTRICALREQUIREMENTS(cont.} Read these instructions completely © Do not change the plug on the power cord of and carefully. this •IMPORTANT- save these instructions air conditioner.
  • Page 13 All GE Models Kit for window installation. RAKS6A100 GE RAB13, 14 & 15 Fits all GE wall cases 26"W x 18"H x 24"D. (ACLB & RCL Chassis) RAK1072 Hotpoint ACXB10 & 11 Adapts an older Hotpoint wall case to a "J" model chassis.
  • Page 14: Installing A J-Model In An Existing Wall Case

    Installation Instructions INSTALLING A J-MODEL IN AN EXISTING WALL CASE Read these instructions completely and carefully. ITI REMOVE LOCKING PLATE ON FRONT 141REINSTALL LOCKING PLATE WITH TAB LEFT SIDE BEHIND WALL CASE FLANGE. TIGHTEN SCREW [] ATTACH POWER CORD TO BASE PAN WITH CLAMP [] REMOVE ALL SHIPPING PADS (IF PRESENT) INSIDE AIR CONDITIONER...
  • Page 15: Installation

    Installation Instructions INSTALLING THROUGH THE WALL Read these instructions completely and carefully. ITI PREPARE OPENING IN WALL 131 SUPPORT REQUIREMENTS FOR AIR CONDITIONER Make certain a wall receptacle is available close to the hole location or make arrangements to install Mortar between the case and the brick wall around a receptacle.
  • Page 16: Window Installation--Optional

    Installation Instructions WINDOW INSTALLATION--OPTIONAL ,6,WARNING! Risk o_ injury Installation must with t hese comply guidelines. Requires optional accessory kits RAK65A1 and Wall Sleeve RAB46A, 47A or 48A Read these instructions completely and carefully. Vinylwindowgasket Sillsupport Case side gasket ( 2) bra_ 2 angles hand)
  • Page 17 Installation Instructions STORM WINDOW REQUIREMENTS WOOD PIECES WIDTH: 2" A storm window frame will not allow the air conditioner to tilt towards the outside and will keep LENGTH: Long enough to fit inside the window frame. it from draining properly. To adjust for this, attach THICKNESS: To determine the thickness, place a piece a piece of wood to the stool.
  • Page 18 Installation Instructions WINDOW INSTALLATION--OPTIONAL (cont.) 141PREPARE WINDOW Mork the centerline of the stool. Meosure from the rBI Meosure 12_" from the centerline on both sides for the sill support brockets. centerline 1B_" on both sides for the ponel cuts. Sill Centerline ,_.
  • Page 19 Installation Instructions [] MEASURE, CUT AND INSTALL FILLER Angle PANELS Gasket-_ [_] Measure from the edge of the panel marks (see Prepare the Window)to the inside of the window track on each side (A and B). Angle_ TypeC (painted Windowtrack Gasket ___*L_nel screws) 13_"...
  • Page 20 Installation Instructions WINDOW INSTALLATION--OPTIONAL (cont.) r_l INSTALL CASE IN WINDOW With the window closed, mark where the window sash meets the case. Peel off the backing from the bottom window gasket, Peel off the backing from the case top gasket. FB] Place the gasket on the stool and over the Hold on to the case, open the window and place brackets, even with the rear edge, sticky...
  • Page 21 Installation Instructions [] INSTALL WINDOW GASKET AND LOCKING BRACKET _-] Cut the foam top window gasket to the window Attach the window locking bracket with width. I type E screw. r_ stuff the foam between the glass and the window to prevent air and insects from getting into the room.
  • Page 22: Troubleshooting Tips

    Before you coil for service... Troubleshooting Tips:Save time and money! Review the chart below first ond you may not need to coil for service. Possible Causes What To Do Theair conditioner • lake surethe air conditionerplugis pushedcompletely doesnotstart is unplugged, intothe outlet.
  • Page 23: Warranty

    USA and Canada. If the product is located in on area where service by o GE Authorized Servicer is not available, you may be responsible for o trip charge or you may be required to bring the product to on Authorized GE Service location for service.
  • Page 24 Contact Us GEAppliunces.corn If you are not satisfied with the service you receive from GE,contact us on our Website with all the details including your phone number, or write to: General Manager, Customer Relations GEAppliances,Appliance Park Louisville,KY40225 Register Your Appliance GEAppliunces.corn...

Table of Contents