(Early models of RC-210/220 may not have the proper cable assembly that
allows powering to take place at the DigiCart end. Subsequently, the power
must be connected directly at the RC-210/220.)
For cable runs longer than 25 feet (8 meters), you should connect the DC
power supply directly into the rear panel of the Remote Control. This
prevents problems resulting from voltage drops or current loss over a long
cable run.
CABLE INTERCONNECTION BETWEEN RC-220 AND DIGICART
Check the REMOTE ADDRESS selection under the SETUP MENU on the
DigiCart. This should be set to ADDRESS 01 for Machine 1, ADDRESS 02
for Machine 2, ADDRESS 03 for Machine 3, and ADDRESS 04 for Machine
4 on the RC-220. (For applications involving only one DigiCart and the
RC-220, set the REMOTE ADDRESS on the DigiCart to ADDRESS 01, and
always select Machine 1 on the RC-220.)
(For information on interconnection between multiple digicarts and a
single RC-220, see Appendix A.)
The Remote Control should be connected before powering up the DigiCart.
If the Remote is connected after the DigiCart's power is turned on,
simultaneously press the SEC and FILE XFER (DNET XFER on DigiCart/II
Plus) buttons on the DigiCart's front panel. This will "soft boot" the DigiCart
and re-initialize the system.