E100 Setup From The Copier Touch Panel - Fiery TASKalfa 3051ci Configuration

Printing system (11),(12),(13),(14) configuration and setup guide (fiery e100)
Hide thumbs Also See for TASKalfa 3051ci:
Table of Contents

Advertisement

S
C
T
P
28
ETTING UP THE
OPIER
OUCH
ANEL

E100 Setup from the copier touch panel

When you perform Server Setup from the copier touch panel, you configure the E100 to
receive jobs over the network systems that are used at your site, including setting network
addresses and names to be used by computers, servers, and the E100 when they communicate
with each other.
Before performing Server Setup, confirm that the E100 is connected to an active network.
The E100 queries the network for zones, servers, and server-based queues. If you perform
setup without a connected and functioning network, default settings are used that may not
meet your needs.
Configure options only for the network systems that are currently used at your site. If your
network requirements change, you can change these settings at any time. If the E100 is
configured to enable more than one protocol, it automatically switches to the correct protocol
when it receives a print job.
The submenus and options appear in sequence. Default values, where applicable, are
underlined. Words shown in italics indicate that a product- or site-specific value is displayed.
Server Name
Default server name
Enter a name for the E100 (up to 15 characters long). This is the name by which the E100
appears on the network.
If you have more than one E100, do not assign them the same name.
N
:
OTE
Ethernet Speed
Auto, 10 Mbps Half-Duplex, 100 Mbps Half-Duplex, 10 Full-Duplex, 100 Full-Duplex
Choose the appropriate speed of the network. Choose Auto in any of these cases:
• The network speed is unknown.
• The network environment is mixed.
• The network uses 1Gbps.
IPv4 Address Type
Automatic, Manual
Choose whether to allow the E100 to obtain its Ethernet IP address automatically by
searching the network, or enter this information manually.
IP Address
127.0.0.1
If you choose Manual, enter the E100 IP address for Ethernet. This IP address, unlike an IP
address set automatically, remains the same if you restart the E100. You must change the
default to a valid address for your network.

Advertisement

Table of Contents
loading