Parameter Setting - Fujitsu Solaris PCI GigabitEthernet 3.0 User Manual

Pci gigabitethernet 3.0 update1 for solaris operating system
Table of Contents

Advertisement

Parameter
LinkSpeed_A *2
DuplexCapabilities_A *2
FlowControl_A *3
Role_A *4
fjgi_mtu *5
*1: When PW008GE5 or PW0G8GE2 is used, it is possible to set name="FJSV,pgtb". When PW008GE4
or PW0G8GE1 is used, it is possible to set name="FJSV,pgsb". It becomes the same meaning
as having specified name="fjgi" in both cases.
*2: Parameter is supported on 10/100/1000Base-T (PW008GE5, PW0G8GE2, SE0X7GD1X, PW008QG1,
SE0X7GQ1X) adapters and PRIMEPOWER250/450 secondary LAN port.
*3: Parameter is effective only when AutoNegotiation_A=On. When AutoNegotiation_A=Off, with
10/100/1000 Base-T, it becomes FlowControl_A=None. And with 1000 Base-SX, it becomes
FlowControl_A=Rem.
*4: Parameter is supported on 10/100/1000Base-T (PW008GE5, PW0G8GE2, SE0X7GD1X, PW008QG1,
SE0X7GQ1X) adapters and PRIMEPOWER250/450 secondary LAN port in 1000Mbps mode only.
*5: Parameter is supported only in Solaris 9 or later, and when the following patch for PRIMEPOWER
is applied.
In the case of Solaris 9 OS: 114994-13 or later
In the case of Solaris 10 OS: 120462-06 or later

[Parameter Setting]

The following shows how to set the parent and unit-address parameter in the fjgi.conf file.
● Find the fjgi device tree, device node and instance number in the /etc/path_to_inst
Value
Off
Auto-Negotiation is disabled. (Fixed mode)
Connection speed of 1000, 100, or 10 Mbps is
set based on negotiation with the remote
Auto (default)
device.
(This can only be set when
AutoNegotiation_A=On.)
1000
Connect at 1000Mbps.
100
Connect at 100Mbps.
10
Connect at 10Mbps.
Indicating that both Full-Duplex and
Half-Duplex are being supported.
Both (default)
(This can only be set when
AutoNegotiation_A=On.)
Half
Half-Duplex operation is allowed.
Full
Full-Duplex operation is allowed.
Flow control is performed according to a setup
Auto (default)
of partner equipment.
Only flow control from the remote machine is
Rem
allowed. Flow control to the remote machine
is not allowed.
Only flow control from the main unit is
LocSend
allowed. Flow control from the remote machine
is not allowed.
None
Flow control is disabled.
Master or Slave is set based on negotiation
with the remote device.
Auto (default)
(This can only be set when AutoNegotiation_A=
On.)
Master
Communication by Master.
Slave
Communication by Slave.
1500 to 9000
MTU size is specified.
3.3 Operation Mode Setup
Description
27

Advertisement

Table of Contents
loading