Reference Information: MB15F88UL
Frequencies: 2490 to 2550 MHz
Step Size:
200 kHz
Hop Time:
Less than 2 s
Charge Pump: 6.0 mA
VCO Sens:
52 MHz/V
Test Results
Phase Noise = -76.3 dBc/Hz
2490 to 2550 MHz = 144 s
Switching Times
Loop Filter values
Spurious = -67.2 dBc
2550 to 2490 MHz = 133 s