Yamaha DG60FX-112 Service Manual page 32

Service manual
Hide thumbs Also See for DG60FX-112:
Table of Contents

Advertisement

DG60FX-112
6: DSP Electric Characteristic
• Using the UP and DOWN switches, select "6" and
then press the STORE switch. The same output level
is obtained when No. at the right end is "0" and when
it is "1".
• To check the output level, noise level and distortion
factor, enter the signal to be measured (short the input
with GND for the noise level check).
• Initial setting: HIGH/LOW SW(SW101)
VR
Center, OUTPUT VR
•••
ITEM
1. INPUT sensitivity
2. INPUT sensitivity
3. INPUT sensitivity
4. INPUT sensitivity
5. INPUT sensitivity
6. INPUT sensitivity
7. INPUT sensitivity
32
OFF(LOW),
•••
MAX
•••
INPUT
CN101(INPUT) -20dBm(1kHz)
CN101(INPUT) -20dBm(10kHz)
CN101(INPUT) -20dBm(100Hz)
CN101(INPUT) -20dBm(100Hz)
CN101(INPUT) -20dBm(10kHz)
CN101(INPUT) -20dBm(1kHz)
CN101(INPUT) -20dBm(1kHz)
OUTPUT
CN102 1pin(OUT R) -6.0dBm+/-3dB
CN102 1pin(OUT R) -6.0dBm+/-3dB
CN102 1pin(OUT R) -6.0dBm+/-3dB
CN102 3pin(OUT L) -24.0dBm+/-3dB
CN102 3pin(OUT L) -24.0dBm+/-3dB
CN102 3pin(OUT L) -24.0dBm+/-3dB
JK2(Digital out) Lch -18dBm+/-3dB Rch 0dBm+/-3dB