10
commit operation. Use separate commit operations to commit the two configurations.
[PR/490542]

Infrastructure

On J-EX Series switches, MAC addresses not present in the forwarding database (FDB)
because of hash collision are not removed from the Ethernet switching process (
These MAC addresses do not age out of the Ethernet switching table even if traffic is
stopped completely and are never relearned when traffic is sent to these MAC
addresses, even when there is no hash collision. As a workaround, clear those MAC
addresses from the Ethernet switching table. [PR/451431]
On J-EX Series switches, the static neighbor discovery protocol (NDP) entries for IPv6
addresses are cleared automatically after some time. [PR/453710]
On J-EX8200 switches, when IGMP snooping is enabled on an interface, the IPv6
multicast Layer 2 control frame is not forwarded to other interfaces in the same VLAN.
[PR/456700]
On J-EX4200 switches with GRES enabled, when a backup member switch has a route
to a destination whose egress member is on the backup member itself, packets
generated on the backup member egress out of the switch. [PR/506119]
On J-EX Series switches, the
to execute. [PR/509303]
On J-EX4200 switches, the headers in ARP requests sent from a virtual IP address
contain the virtual IP address as the source address instead of the virtual MAC address.
[PR/512488]
On J-EX8200 switches with a 10-gigabit uplink port, when the Routing Engine is
switched over, the 10-Gigabit uplink port stops forwarding traffic in the egress direction.
[PR/515011]
On J-EX8200 switches, the output of an SNMP walk on
does not show the temperature for line cards. [PR/524112]
jnxFruTemp

Interfaces

On J-EX8200 switches, aggregated Ethernet interfaces might go down and come back
up for a few minutes while the switch is updating many routes. [PR/416976]
On J-EX8200 switches, after enabling GRES. you might not be able to connect to the
management interface on the backup Routing Engine using Telnet, and an existing
Telnet session with the management interface on the backup Routing Engine might
become inactive. [PR/520966]
On J-EX8200 switches, the following message is logged frequently in the
file:
/var/log/mastership
mcontrol_refresh_mastership: time 6
These messages are harmless.
clear interface statistics all
eswd
command takes a long time
and
jnxOperatingTemp
).

Advertisement