Temperature Requirements; Table 3.1 Temperature Requirements At Measurement Points - Fujitsu MCM3064SS Product Manual

Fujitsu computer drive user manual
Table of Contents

Advertisement

Installation Requirements
(b) IC (controller, read Amp)
Figure 3.1 Surface temperature measurement point (2 of 2)

3.1.2 Temperature requirements

Table 3.1 shows the temperature requirement at the measurement point shown in
Figure 3.1.

Table 3.1 Temperature requirements at measurement points

Measurement point
Inside the cartridge
IC (controller) surface
IC (read Amp.) surface
*1
The following describes a procedure for measuring the temperature inside a
cartridge.
1) At the bottom of the cartridge, open a hole large enough for the thermocouple
to be inserted as shown in Figure 3.1.
2) Disassemble the cartridge.
3-2
60°C for the optical disk cartridges recommended by Fujitsu (except 1.3
GB).
IC (controller)
IC (read Am p)
Maximum allowable surface temperature
55°C (*1)
85°C
85°C
C156-E228-02EN