Installation Requirements
(b) IC (controller, read Amp)
Figure 3.1 Surface temperature measurement point (2 of 2)
3.1.2 Temperature requirements
Table 3.1 shows the temperature requirement at the measurement point shown in
Figure 3.1.
Table 3.1 Temperature requirements at measurement points
Measurement point
Inside the cartridge
IC (controller) surface
IC (read Amp.) surface
*1
The following describes a procedure for measuring the temperature inside a
cartridge.
1) At the bottom of the cartridge, open a hole large enough for the thermocouple
to be inserted as shown in Figure 3.1.
2) Disassemble the cartridge.
3-2
60°C for the optical disk cartridges recommended by Fujitsu (except 1.3
GB).
IC (controller)
IC (read Am p)
Maximum allowable surface temperature
55°C (*1)
85°C
85°C
C156-E228-02EN