Technical Data - Electrolux EHG 679 B Instruction Booklet

Hide thumbs Also See for EHG 679 B:
Table of Contents

Advertisement

Instructions for the Installer
Engineer technical data
OVERALL DIMENSIONS
Width:
580 mm.
Depth:
510 mm.
Height:
88 mm.
Weight:
9,8 Kg.
CUT OUT DIMENSIONS
Width:
550 mm.
Depth:
470 mm.
Thickness: 40 mm.
Ignition HT Spark
Spark Generator
Spark Gap
Rear Left Burner (semi rapid)
Heat Input
Front Left Burner (rapid)
Heat Input
2.9 kW Natural Gas (9895 BTU/HR)
2.7 kW L.P.G. (9212 BTU/HR)
NOMINAL THERMAL
POWER
NOMINAL FLOW
RATE
NOZZLE REFERENCE
NOMINAL THERMAL
POWER
NOMINAL FLOW
RATE
NOZZLE REFERENCE
Burner
Dia. Tap By-pass
1/100 mm
Auxiliary
Semi-rapid
Rapid
Aeration adjustment none
12
Ispra Control's BF 50046 - 240V 0.6 YA T 120
Fixed
1.9 kW (6483 BTU/HR)
BURNER
RAPID
(large)
POSITION
MAX
kW
2.9
3
m
/h
0.276
119
1/100 mm
kW
2.7
g/h
195
86
1/100 mm
Tap colour
28
Red/Red
32
Blue/Blue
40
Black/Black
SUPPLY CONNECTIONS
Gas:
RC 1/2 inch (1/2 inch male) Rear right hand corner
Electric:
230-240V 50Hz supply, 3 core flexible cable with
non rewireable plug fitted with a 3 amp cartridge
fuse.
This appliance complies with the EEC Directive No
89/336, concerning suppression of radio electrical
interference.
Rear Right Burner (semi rapid)
Heat Input
Front Right Burner (auxiliary)
Heat Input
SEMI-RAPID
AUXILIARY
(medium)
MIN
MAX
MIN
MAX
0.65
1.9
0.45
1.0
0.062
0.181
0.043
0.095
Adjust.
96
Adjust.
70
0.65
1.9
0.45
1.0
46.8
137
32.4
72
40
71
32
50
CLASS APPLIANCE: 3
APPLIANCE
CATEGORY: II2H3+
APPLIANCE
GAS SUPPLY: Natural gas G20 / 20mbar
1.9 kW (6483 BTU/HR)
1.0 kW (3412 BTU/HR)
(small)
MIN
0.33
0.031
Adjust.
0.33
23.8
28