TROUBLE SHOOTING
Never try to repair or dismantle the unit yourself. Before calling for assistance please check
the points below.
The unit doesn't run.
The unit seems to
extract little water.
The unit seems to do
nothing.
Too noisy.
The unit's fan doesn't
seem to be revolving.
The continuous
drainage is not working.

TECHNICAL DATA

Model
Mains
Power consumption
(at 32 °C, RH 90 %)
Heater
Moisture removal
(at 32 °C, RH 90 %)
Refrigerant
Refrigerant load
Working temperature
Dimensions (W x D x H)
Net weight
Due to our continuous R+D program, specifications may change without prior notice.
For current specifications please refer to the rating label on your machine.
14
Is the machine plugged in?
Is the mains power supply on?
Is the water tank full indicator on? (If so, the water tank is full or it isn't
positioned properly).
Are too many windows or doors open?
Is there something in the room producing lots of heat?
Is the room cold – the colder the air the less moisture the unit will extract.
Is the filter dirty?
Is the room humidity already quite low?
Is the filter dirty?
Is the air intake or outlet blocked?
Is the room humidity already quite low?
Is the room temperature below 5 °C? The fan may run without the compressor.
Is the machine positioned unevenly so as to create vibration?
Is the floor underneath the unit uneven or loose fitting?
Is there any foreign body interfering with the unit?
Is the filter blocked?
Is there any foreign body interfering with the unit?
Does the hose have a downward slope throughout its entire length?
Is there a kink or sharp bend in the hose?
W
W
L/24h
g
°C
cm
kg
PLDA 19EH
220 - 240 V / 50 Hz
300
600
18
R-134A
155
5 - 35
42 x 24 x 60
16
PLDA 25EH
390
24
200
16.5