The BNC port on the hub, with the BNC T-connector and the 50
connecting to a thin coaxial segment.

Technical Specifications

General Specifications
Network Protocol and Standards Compatibility
IEEE 802.3i, 10BASE-T, 10BASE-2, 10BASE-5 Ethernet
Data Rate
Interface
Power Consumption
Model EN104 hub
Model EN108 hub
Model EN116 hub
DC Output Voltage (Power Adapter):
Model EN104 hub
Model EN108 hub
Model EN116 hub
Physical Specifications
Dimensions:
Model EN104 hub
Model EN108 hub
Model EN116 hub
Weight:
Model EN104 hub
Model EN108 hub
Model EN116 hub
Environmental Specifications
Operating temperature:
Operating humidity:
Electromagnetic Emissions
CE mark, commercial
FCC Part 15 Class A
EN 55 022 (CISPR 22), Class A
VCCI Class 1 ITE
Electromagnetic Susceptibility
CE mark, commercial
Electrostatic discharge (ESD):
Radiated electromagnetic field:
Electrical fast transient/burst:
Electrical surge:
Safety Agency Approvals for Power Adapter
CE mark, commercial
UL listed (UL 1950)
CSA certified (CSA 22.2 #950)
TUV licensed (EN 60 950)
T-Mark
Model EN104/EN108/EN116 Ethernet Hub Installation Guide
BNC T-connector
50
terminator
10 Mbps, Manchester encoded
10BASE-T ports (RJ-45), BNC port,
AUI port (Model EN108 hub and Model EN116 hub only)
11.0 W
16.5 W
20.5 W
1.2 V DC@ 1200 mA max., 47 to 63 Hz
12 V DC @ 1200 mA max., 47 to 63 Hz
12 V DC @ 1200 mA max., 47 to 63 Hz
3.37 by 4.0 by 1.1 in.
94 by 101 by 28 mm
6.2 by 4.0 by 1.1 in.
158 by 101 by 28 mm
11.3 by 4.0 by 1.1 in.
286 by 101 by 28 mm
0.74 lb (0.34 kg)
1.17 lb (0.53 kg)
1.97 lb (0.89 kg)
0 to 40 C (32 to 104 F)
90% maximum relative humidity, noncondensing
IEC 801-2, Level 2/3/4
IEC 801-3, Level 2
IEC 801-4, Level 2
IEC 801-5, Level 2
terminator, is used for