Download Print this page

How To Assemble The Connector; Operating Distances - Panasonic Videolarm POD9CFW Installation Instructions Manual

Outdoor domed housings

Advertisement

WJ-HD316A
WU-CU650
Wiring Color Code
Power and Control Inputs
POD9C
CONNECTOR A
CAMERA POWER [13 watts WV-CS954 / WV-CS574]
1
24 VAC Live
2
24 VAC Live
3
Green
4
Not Used
CONNECTOR B
ACCESSORY POWER [52 watts Heater/Blower]
1
24 VAC Live
2
24 VAC Live
3
Green
4
Not Used
Pan/Tilt Unit Only
CONTROL
1
Ground
2
TXB (RS485)
3
TXA (RS485)
4
RXB (RS485)
5
RXB (RS485)
ALARM IN (8-pin)
1
Alarm In 1
2
Ground
3
Alarm In 2
4
Ground
5
Alarm In 3
6
Ground
7
Alarm In 4
8
Ground
ALARM OUT (4-pin)
1
Alarm Out 1
2
Ground
3
Alarm Out 2
4
Ground
CAUTION: For lightning protection of the camera
and heater/blower, the pin 3 of the connector
must be connected to real electrical ground.
Black
White
Green
Red
White
Green
Brown
Red
Orange
Yellow
Green
Black
Brown
Red
Orange
Yellow
Light blue or green
Blue
Purple
Gray
White
Pink
Yellow, Green, or Light blue

HOW TO ASSEMbLE THE CONNECTOR

• Strip back the cable jacket approximately 0.1 inch
(3 mm) and separate the individual conductors.
Approx. 0.1"
Insert
Up
Contact
Prepare the individual conductors for clamping. If
clamping, use Molex brand tool part number 57027-
5000 (for UL-listed-style cable UL1015) or 57026-5000
(for UL-listed-style cable UL1007).
After clamping the contacts, push them into the
proper holes in the connector housing until they
snap in place.
CAUTIONS
• Shrinking the cable-entry seal is a onetime
procedure. Do not shrink the cable-entry seal
until it has been determined that the unit is
functioning.
• CONNECT THIS TO A 4 VAC CLASS  POWER
SUPPLY ONLY.
3
1
CAUTION: TO PREVENT FIRE OR SHOCK HAZARD, THE
UL-LISTED WIRE VW-1, STYLE 1007, SHOULD BE USED
FOR THE CABLE FOR 24 VAC INPUT TERMINALS.

OPERATING DISTANCES

Awg Size
Impedance
Awg #12
1.71 ohm/1000 ft.
Awg #14
2.73 ohm/1000 ft.
Awg #16
4.35 ohm/1000 ft.
Awg #18
6.92 ohm/1000 ft.
- 4 -
Wire
Up
Contact
4
3
4
1
2
2
Max Distance
440 ft.
270 ft.
170 ft.
100 ft.
Wire

Advertisement

loading

This manual is also suitable for:

Videolarm pod9cwVideolarm pod9cfVideolarm pod9c