SMC Networks EZ Connect Quick Install Manual

SMC Networks EZ Connect Quick Install Manual

Usb/ethernet cable modem
Hide thumbs Also See for EZ Connect:

Advertisement

Quick Links

EZ Connect
USB/Ethernet Cable Modem
• Complies with DOCSIS 1.0 cable modem
requirements
• Concurrent USB and Ethernet support
• Up to 40Mpbs downstream and 10Mbps upstream
• Supports SNMP management
Quick Install Guide
SMC8002CM-US

Advertisement

Table of Contents
loading

Summary of Contents for SMC Networks EZ Connect

  • Page 1 EZ Connect ™ USB/Ethernet Cable Modem • Complies with DOCSIS 1.0 cable modem requirements • Concurrent USB and Ethernet support • Up to 40Mpbs downstream and 10Mbps upstream • Supports SNMP management Quick Install Guide SMC8002CM-US...
  • Page 2: Table Of Contents

    Contents Introduction Key Features Description of Hardware LED Functions Installing the Modem Package Contents Mounting the Modem System Requirements Connecting the Modem Installation USB Installation for Windows 98, Window 2000 and Windows Me Ethernet Installation for Windows Windows 95/98/NT Windows 2000 Making a Connection to the Ethernet Port Product Specifications General Specifications...
  • Page 3 Contents...
  • Page 4: Introduction

    Introduction The EZ Connect Cable Modem provides high-speed Internet access over the the same cable network system that brings cable TV service to the home. The data transmission rate on the cable connection is asymmetric, in that it provides a higher data rate in the downstream (receive) direction than in the upstream (transmit) direction.
  • Page 5: Description Of Hardware

    Quick Installation Guide Description of Hardware The SMC8002CM-US is an external DOCSIS-based cable modem product for high-speed Internet access applications.The modem provides an optional USB or Ethernet connection to a PC or LAN. In an Ethernet LAN environment, it supports up to 16 PCs, allowing shared Internet access.
  • Page 6: Led Functions

    Installing the Modem LED Functions The EZ Connect Cable Modem contains four LEDs on the top panel. The operational status of the modem is indicated by the LED conditions listed below. Status Description On Red Power is being supplied to the modem.
  • Page 7: Mounting The Modem

    Quick Installation Guide Mounting the Modem The SMC8002CM-US comes with a slot-in stand with which it may be mounted vertically or horizontally. To do this, simply slide the modem on to the stand with the flanges provided on the base or the side. The two mounting options are illustrated below. RJ-45 Port USB Port Cable Connector...
  • Page 8: Connecting The Modem

    Installing the Modem Connecting the Modem Before connecting the EZ Connect Cable Modem, contact your cable service provider and check the following points: • Be sure that your service provider supplies a two-way data link. • Check that they have set up an Internet Access Account. To do this you will need to provide information that may include the product number and the modem MAC address.
  • Page 9: Installation

    Follow the instructions given to install the driver. Reboot your computer when prompted. Ethernet Installation for Windows To connect the EZ Connect Cable Modem to a computer through the Ethernet port, the computer must have an Ethernet network adapter card installed, and be configured for TCP/IP protocol.
  • Page 10: Making A Connection To The Ethernet Port

    Installing the Modem Making a Connection to the Ethernet Port You can use straight-through Network Adapter Card twisted-pair cable to connect the Ethernet port on the modem to a PC. Make sure you have installed a 10/100Mbps network adapter card in the PC.
  • Page 11: Product Specifications

    Quick Installation Guide Product Specifications General Specifications Standards Conformance DOCSIS 1.0, IEEE 802.3, IEEE 802.3u, USB 1.1 Cable Modem Requirements Modulation Downstream: 64-QAM/256-QAM (receive) Upstream: QPSK/16-QAM (transmit) Data Rate Downstream: 30.432 Mbps (64-QAM), 42.88 Mbps (256-QAM) Upstream: 320, 640, 1280, 2560, 5120 kbps (QPSK), 640, 1280, 5560, 5120, 10240 kbps (16-QAM) Frequency Range Downstream: 91 MHz ~ 857 MHz...
  • Page 12: Troubleshooting

    Troubleshooting Troubleshooting Cannot Connect to the Internet • Confirm that you have established an account with your service provider and that a two-way cable service is provided. • Check that all cables are connected to the modem and PC. Verify that the proper cable type is used and its length does not exceed specified limits.
  • Page 13: Port And Cable Assignments

    Quick Installation Guide Port and Cable Assignments DO NOT plug a phone jack connector into any RJ-45 port. Use only Caution: twisted-pair cables with RJ-45 connectors that conform with FCC standards. An Ethernet twisted-pair link segment requires two pairs of wires. Each wire pair is identified by two different colors.
  • Page 14: Straight-Through Wiring

    Port and Cable Assignments Straight-Through Wiring If the twisted-pair cable is to join two ports and only one of the ports has an internal crossover (MDI-X), the two pairs of wires must be straight-through. Straight-Through RJ-45 Pin Assignments End 1 End 2 1 (RD+) 1 (TD+)
  • Page 15: Emi Certification

    Quick Installation Guide EMI Certification FCC Class B Certification (USA) This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions: This device may not cause harmful interference, and This device must accept any interference received, including interference that may cause undesired operation.
  • Page 16: Ce Mark Declaration Of Conformance

    EMI Certification CE Mark Declaration of Conformance This information technology equipment complies with the requirements of the Council Directive 89/336/EEC on the Approximation of the laws of the Member States relating to Electromagnetic Compatibility and 73/23/EEC for electrical equipment used within certain voltage limits and the Amendment Directive 93/68/ EEC.
  • Page 17: Safety Compliance

    Quick Installation Guide Safety Compliance Underwriters Laboratories Inc. (USA) Important! Before making connections, make sure you have the correct Cord Set. Check it (read the label on the cable) against the following specification list. Operating Voltage Cord Set Specifications 120 Volts UL Listed/CSA Certified Cord Set Minimum 18 AWG Type SVT or SJT three conductor cord...
  • Page 18: Warranty

    Warranty Warranty SMC warrants to the original owner that the product delivered in this package will be free from defects in material and workmanship for a period of three (3) years from the date of purchase from SMC or its Authorized reseller. For the warranty to apply, you must register your purchase by returning the registration card indicating the date of purchase and including proof of purchase.
  • Page 19 FOR TECHNICAL SUPPORT, CALL: From U.S.A. and Canada (24 hours a day, 7 days a week) (800) SMC-4-YOU; (949) 679-8000; Fax: (949) 679-1481 From Europe (8:00 AM - 5:30 PM UK Time) 44 (0) 118 974 8700; Fax: 44 (0) 118 974 8701 INTERNET E-mail addresses: techsupport@smc.com...

This manual is also suitable for:

Ez connect smc8002cm-us

Table of Contents