Operating Manual
Operation
Response Format:

Discipline On

Command Format:
Description:
The oscillator discipline is turned on. When the conditions are favorable, the discipline
algorithm will control the oscillator.
Response Format:

Dynamic Gain Control

Command Format:
Description:
The dynamic gain value determines the response time of the control loop. This command
sets the upper and lower limit.
Fgg.g - Dynamic Gain Floor; the lowest value allowed for dynamic gain.
Cgg.g - Dynamic Gain Ceiling; the highest value allowed for dynamic gain.
With the default values for Km, Ko1, Ko2, and Disgain, the dynamic gain will produce the
following approximate time constants in the discipline control loop:
PN 8500-0150, Rev. A, May 2005