Physical And Electrical Data - York TCGD12 S21S2H Technical Manual

Split-system air conditioners 13 seer – r-22
Table of Contents

Advertisement

400034-YTG-B-0708

Physical and Electrical Data

MODEL
Unit Supply Voltage
1
Normal Voltage Range
Minimum Circuit Ampacity
Max. Overcurrent Device Amps
Min. Overcurrent Device Amps
Compressor Type
Rated Load
Compressor Amps
Locked Rotor
Crankcase Heater
Fan Motor Amps
Rated Load
Fan Diameter Inches
Rated HP
Fan Motor
Nominal RPM
Nominal CFM
Face Area Sq. Ft.
Coil
Rows Deep
Fin / Inches
Liquid Line Set OD (Field Installed)
Vapor Line Set OD (Field Installed)
4
Unit Charge (Lbs. - Oz.)
Charge Per Foot, Oz.
Operating Weight Lbs.
Models with "H" on the end of the model number have a factory installed start kits.
1. Rated in accordance with ARI Standard 110, utilization range "A".
2. Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection.
3. Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection.
4. The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than
15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value.
A
2
TCGD12
TCGD18
S21S2(H)
S21S2(H)
6.2
9.5
2
15
15
3
15
15
Rotary
Rotary
4.5
7.2
26.0
40.0
No
No
0.50
0.50
18
18
1/12
1/12
1100
1100
1350
1550
8.1
9.7
1
1
23
23
3/8
3/8
5/8
5/8
3 - 2
3 - 0
0.66
0.66
96
110
C
B
TCGD24
TCGD30
TCGD36
S21S2(H)
S21S2(H)
S21S2(H)
208-230V, 1φ, 60Hz
187 to 252
11.3
14.0
18.2
15
20
30
15
15
20
Rotary
Recip
Recip
8.4
10.6
13.4
47.0
61.0
78.0
No
No
No
0.80
0.80
1.4
18
18
18
1/8
1/8
1/4
1075
1075
1100
1850
1950
2400
9.7
11.3
12.1
1
1
1
23
23
23
3/8
3/8
3/8
3/4
3/4
3/4
3 - 13
3 - 7
3 - 15
0.68
0.68
0.68
130
150
160
All dimensions are in inches. They are subject to change
without notice. Certified dimensions will be provided upon
request.
Dimensions
Unit
(Inches)
Model
1
A
12
24
23-1/2
23-1/2
18
28
24
28
23-1/2
30
32
23-1/2
36
34
23-1/2
42
34
48
34
60
40
1. Including Fan Guard.
2. Expander fitting required for 1-1/8" linset.
TCGD42
TCGD48
S21S2(H)
S21S2(H)
19.9
22.7
30
35
20
25
Recip
Recip
14.7
17.0
78.0
86.0
No
No
1.5
1.5
22
22
1/4
1/4
850
850
3000
3000
16.5
16.5
1
1
23
23
3/8
3/8
7/8
7/8
4 - 2
4 - 5
0.70
0.70
175
176
Refrigerant Connection
Service Valve Size
B
C
Liquid
23-1/2
23-1/2
23-1/2
23-1/2
3/8"
23-1/2
29
29
29
29
29
29
Johnson Controls Unitary Products
TCGD60
S21S2
33.5
50
35
Scroll
25.6
150.0
No
1.5
22
1/4
850
3300
19.75
1
23
3/8
1-1/8
5 - 4
0.76
200
Vapor
3/4"
7/8"
2
7/8"

Advertisement

Table of Contents
loading

Table of Contents