COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO.
INDOOR COIL MODEL NO.
CONDENSING
ENTERING AIR
TEMPERATURE
65
75
85
95
105
115
125
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
Air Handler
Coil
MA20D
FC/MC62D
MV20D
FC/MC62D
Subject to change without notice. Printed in U.S.A.
Copyright © 2008 by Johnson Controls, Inc. All rights reserved.
TCGD60S21S2
FC/MC62
IDCFM
1750
ID DB (°F)
80
80
75
ID WB (°F)
57
62
62
T.C.
57.5 58.5 57.1 62.2 60.7 59.2 60.1 58.2 63.4 62.8 61.0 61.6 59.3 64.5 64.9
S.C.
54.4 51.6 42.7 41.3 29.2 55.9 54.9 45.2 43.3 30.4 57.3 58.1 47.6 45.4 31.6
KW
2.9
3.0
3.0
T.C.
55.4 56.6 54.6 60.1 59.4 57.4 58.3 55.7 61.2 60.1 59.4 60.0 56.8 62.3 60.8
S.C.
52.4 50.5 41.7 40.7 28.8 53.9 53.4 44.2 43.0 30.0 55.5 56.2 46.7 45.3 31.2
KW
3.3
3.3
3.3
T.C.
53.3 54.7 52.1 58.0 58.1 55.5 56.6 53.1 59.0 57.3 57.7 58.4 54.2 60.1 56.6
S.C.
50.3 49.4 40.6 40.1 28.4 52.0 51.9 43.2 42.6 29.6 53.7 54.4 45.8 45.1 30.8
KW
3.7
3.7
3.7
T.C.
51.3 52.7 49.6 56.0 56.7 53.7 54.8 50.6 56.9 54.6 56.1 56.9 51.6 57.8 52.5
S.C.
48.2 48.3 39.5 39.6 28.0 50.0 50.4 42.2 42.3 29.2 51.8 52.6 44.9 45.0 30.4
KW
4.1
4.1
4.1
T.C.
49.1 49.5 45.8 51.8 52.6 51.3 51.4 46.8 52.7 50.5 53.6 53.2 47.8 53.6 48.4
S.C.
45.2 45.4 37.8 38.0 26.8 46.9 47.3 40.3 40.6 28.1 48.5 49.2 42.8 43.3 29.4
KW
4.6
4.6
4.6
T.C.
47.1 46.4 42.2 47.8 48.5 49.1 48.1 43.2 48.7 46.5 51.1 49.7 44.2 49.5 44.5
S.C.
42.3 42.6 36.2 36.4 25.8 43.8 44.3 38.5 39.0 27.1 45.3 45.9 40.7 41.6 28.5
KW
5.2
5.2
5.1
T.C.
45.0 43.3 38.6 43.8 44.5 46.9 44.8 39.6 44.6 42.5 48.7 46.2 40.5 45.4 40.6
S.C.
39.4 39.9 34.5 34.9 24.7 40.8 41.2 36.6 37.4 26.1 42.1 42.6 38.7 40.0 27.5
KW
5.7
5.7
5.6
T.C.
S.C.
1.00
1.01
1.00
1.01
Johnson Controls Unitary Products
Norman, OK 73069
2000
80
80
80
80
67
72
57
62
3.0
3.0
3.0
3.0
3.4
3.5
3.4
3.4
3.8
3.9
3.8
3.8
4.2
4.3
4.2
4.1
4.7
4.9
4.7
4.7
5.2
5.4
5.2
5.2
5.7
5.9
5.7
5.7
KW
Variable Speed
Furnace
1.00
PV8*C20
1.00
P(C,V)9*C20
P(C,V)9*D20
5005 York Drive
75
80
80
80
80
62
67
72
57
62
3.0
3.0
3.1
3.0
3.0
3.4
3.4
3.5
3.4
3.4
3.7
3.8
3.9
3.8
3.8
4.1
4.2
4.3
4.2
4.2
4.7
4.7
4.9
4.7
4.7
5.2
5.3
5.4
5.2
5.2
5.7
5.8
5.9
5.7
5.7
Coil
T.C.
FC/MC62D
1.00
FC/MC62D
0.98
FC/MC62D
1.00
Supersedes: 400034-YTG-A-0408
2250
75
80
80
62
67
72
3.0
3.0
3.1
3.4
3.4
3.5
3.8
3.8
3.9
4.2
4.3
4.4
4.7
4.8
4.9
5.2
5.3
5.4
5.7
5.8
5.9
S.C.
KW
1.01
1.00
1.01
0.98
1.02
1.00
400034-YTG-B-0708