4.2.1 Installation accessories
Table 3 lists the standard and optional
accessories which are available for
the TURBOmax combination boilers.
4.2.2 Unpack the boiler (fig. 11)
Open the boiler carton and remove:
a. protective cardboard sheet
b. top and bottom decorative panels
c. polystyrene packaging
Note: Care should be taken not to
scratch the white surface of the boiler
casing.
Packed in the boiler carton are the
following:
boiler installation template
boiler hanging bracket
gas service valve
fixing screws and wallplugs
installation and user instructions
flue restrictor
domestic hot and cold water
connections and straddle bracket
4.3 Preparation of boiler
location
4.3.1 Select position of boiler.
Refer to Section 3.2 'Boiler Location'
for information regarding siting the
boiler. In general the boiler must be
positioned such that:
there is adequate space around the
boiler for service and maintenance
the boiler can be correctly flued,
i.e. the flue terminal position is sited
in accordance with Section 3.4.1
and the air / flue duct can be
installed in accordance with the
flue installation instructions
supplied.
all necessary pipework can be
connected, including the pressure
relief valve discharge pipe.
14
Table 3: Installation Accessories
Standard Accessories
1. Air/flue duct and terminal accessory
Optional Accessories
1. Vertical air / flue duct (including terminal)
2. Pitched roof adjustable roof tile
(for use with vertical air/flue duct)
3. Flat roof penetration collar
(for use with vertical air/flue duct)
4. 1 m air /flue duct extension
5. 2 m air / flue duct exension
6. Additional 90° elbow for air / flue duct
7. Additional 45° bends (pair) for air / flue duct
8. Additional air / flue duct joint clamps (pair)
9. Se- duct flue kit
10. Internal flue fixing kit
11. Pre - installation connecting group
(includes 300 813)
12. Vaillant boiler replacement connection accessory
13. Pipe cover accessory
14. Plug in 24 hour central heating timeclock
15. Plug in 7 day central heating timeclock
fig. 11
Art. No.
300 807
Art. No.
300 800
9076
9056
300 802
300 803
300 808
300 809
300 806
300 810
8098
8015
300 813
8099
300 820
300 821