Technical Data
L.P.G. Appliances:
VUW 242/1 EB
VUW 282/1 EB
Related documents to be
supplemented by:
BS 5482:
CP for domestic butane
and propane gas
burning installations
Part 1:
Installations in
permanent dwellings
Inlet pressure: Propane
37 mbar (14.6 in W.G.)
Butane
28-30 mbar
(11.0-11.8 in W.G.)
Type
Countries of
Destination
Main burner jet size
Burner setting pressure
25.1 (9.9) Propane
19.3 (7.6) Butane
Restrictor
Delivered gas
Propane
Gross C.V. (s.t.)
Gas consumption (s.t.)
1.09 (Propane)
VUW
VUW
242/1 E B
282/1 E B
GB, IE
GB, IE
16 x 7/075
18 x 7/075
26.6 (10.5) Propane
20.6 (8.1) Butane
2 * 350
2 * 375
G 31 96.65
G 30 125.81
1.27 (Propane)
0.84 (Butane)
0.98 (Butane)
number x mark.
mbar (in W.G.)
mbar (in W.G.)
marking
MJ/m
3
MJ/m
3
m
/h
3
m
/h
3
59