Vaillant auroMATIC VRS 560 Operating And Installation Manual

Vaillant auroMATIC VRS 560 Operating And Installation Manual

Solar differential controller
Hide thumbs Also See for auroMATIC VRS 560:
Table of Contents

Advertisement

Quick Links

For the operator/expert technician
Operating and Installation Manual
auroMATIC 560
Solar Differential Controller
VRS 560
GB

Advertisement

Table of Contents
loading

Summary of Contents for Vaillant auroMATIC VRS 560

  • Page 1 For the operator/expert technician Operating and Installation Manual auroMATIC 560 Solar Differential Controller VRS 560...
  • Page 2: Table Of Contents

    Overview of display ..........7 Display types ............8 Information on installationand operation ..4 5.4.1 Display, main operating level .......8 Vaillant warranty ..........4 5.4.2 Display, info level ............8 Intended use .............4 5.4.3 Display, programming level ........8 Requirements of the installation site ....4 5.4.4 Display, special functions ........8...
  • Page 3: General Information

    PC, the applicable directives in accordance with the type and can be obtained from Vaillant as an accessory. For summary. this purpose, the solar controller is equipped with an eBUS interface.
  • Page 4: Information On Installationand Operation

    Care Vaillant warranty You can clean the casing of the controller with a damp We only grant a Vaillant manufacturers warranty if a cloth and a little soap. suitably qualified engineer has installed the system in accordance with Vaillant instructions. The system owner...
  • Page 5: Functions 4

    Functions 4 Functions In doing so, the cylinder temperature is raised to 71 °C and the corresponding circulation pump is switched on Solar yield (if installed). The anti-legionella function is implemented The solar controller works on the principle of differen- either via an external heater or electrical heating rod if tial temperature control system.
  • Page 6: Special Functions

    4 Functions Special functions 4.12 Solar circuit protection function Please refer to Sec. 5.6 for information on how to acti- If the solar heat exceeds the current heat demand vate the following special functions. (e.g. all cylinders fully charged), the temperature may occur in the collector field may increase rapidly.
  • Page 7: Operation 5

    Operator guidance The controller has a display which consists of symbols, and is designed according to the Vaillant "turn and click" operating concept. You can call up and set values by turning the dial. You can also click the dial in order to call up values within an operating level.
  • Page 8: Display Types

    5 Operation Display types 5.4.3 Display, programming level You can access the level for programming the control- 5.4.1 Display, main operating level ler‘s operating times by pressing the "P" programming The main operating level appears when the appliance is button. You can set timer programs here for reheating switched on.
  • Page 9: Display, Service/Diagnostics Level

    Operation 5 Display Settings 5.4.5 Display, service/diagnostics level Collector sensor 1 temperature The actuators and sensors should be checked by the technician expert. You can access the service/diagnostics level by simulta- neously pressing the programming button "P" and the dial for roughly 3 seconds. All actuators and sensors can be controlled and checked in this level (see Chapter 7 in Collector sensor 2 temperature the installation instructions).
  • Page 10: Setting The Reheating Function Timer Program

    5 Operation Time window Weekday/ Start time End time Operating modes: Block of days M0 - S0 5:30 22:00 Reheating function with timer program — — — — — — Reheating function in constant standby Table 5.3 Default reheating program mode There are four steps to setting the times you want: 1.
  • Page 11: Setting The Timer Program, Circulation Pump

    Operation 5 Error messages 6 Error messages 5.5.4 Setting the timer program, circulation pump You can create a customised timer program for a con- nected circulation pump (only possible for hydraulic The auroMATIC 560 solar controller shows error mes- plan 1), just as you can for the reheating function. sages in the main operating level if there is a problem The controller is equipped with a default program for with the temperature sensor.
  • Page 13: Installation Manual

    Technical data ..........25 Safety instructions ..........3 Regulations ...............3 Sensor characteristics ........ 26 Assembly ............3 Vaillant Service ..........26 Scope of delivery ............3 Assembly of VR 10 standard sensor ....3 Accessories ...............3 4.3.1 VR 10 standard sensor ...........3 4.3.2 VR 11 collector sensor ..........3 Installing the controller housing ......4...
  • Page 14: Notes On The Documentation

    1 Notes on the documentation 2 Description of the unit Notes on the documentation Description of the unit The following information is intended to help you CE label throughout the entire documentation. The CE label indicates that the controller meets the Further documents apply in combination with this oper- basic requirements of the Council of Europe‘s directive ating and installation manual.
  • Page 15: Safety Instructions And Regulations 3

    Have the mixer valve adjusted by your expert troller. technician. 4.3.2 VR 11 collector sensor If a second collector field is connected, it is necessary to install a second collector sensor from the Vaillant acces- sory range. Installation instructions – auroMATIC 560 0020008427_01...
  • Page 16: Installing The Controller Housing

    4 Assembly 5 Electrical installation Installing the controller housing ProE-system wiring The controller is designed to be mounted on a wall and is equipped with System ProE terminal strips. These ter- minals must be used for all connections made at the in- stallation site.
  • Page 17: Wiring According To Hydraulic Plan

    Electrical installation 5 Caution! An optional electrical heating rod (EP) must be installed with an additional relay or contactor with a circuit-breaking capacity of at least 16 A. Never operate an electrical heating rod in connection with the auroMATIC 560 without an additional external relay or contactor.
  • Page 18: Hydraulic Plan 1

    5 Electrical installation Hydraulic plan 1 VRS 560 C1/C2 C1/C2 C1/C2 C1/C2 Kol1 (VR 11) 230 V 230 V ~ 230 V ~ Kol1-P (VR 10) Ertrag LEG/BYP (VR 10) (VR 10) Fig. 5.1 Hydraulic plan 1 with system configuration: one collec- tor field, one solar cylinder, connection option for vari- ous heaters for reheating the cylinder Designation in...
  • Page 19 Electrical installation 5 VC / VK 230V Netz Kol1-P Kol2-P / ZP LEG/BYP LP/UV 1 VRS 560 C1/C2 Kol1 Ertrag Kol2 Fig. 5.2 Connection diagram for hydraulic plan 1 Note LEG/BYP can be used as a legionella protection pump or an electric heater cartridge. Only one of these options can be used.
  • Page 20 5 Electrical installation Hydraulic plan 1: Connection of a second cylinder or swimming pool VRS 560 C1/C2 Kol1 (VR 11) 230 V ~ Kol1-P (VR 10) Ertrag LEG/BYP (VR 10) LP/UV1 (VR 10) (VR 10) 400 V Fig. 5.3 Hydraulic plan 1: Connection of a second cylinder or swimming pool Danger! Danger of scalding due to hot water.
  • Page 21 Electrical installation 5 Designation in Components Designation in Components hydraulic plan/ hydraulic plan/ wiring diagram wiring diagram Yield Sensor for measuring yield (optional) C1/C2 Connections for controlling the heater used for reheating the cylinder LEG/BYP Legionella protection pump or electric heater cartridge Boiler Cylinder sensor 1...
  • Page 22 Danger! draulic plan/wiring Danger of scalding due to hot water. diagram The mixer valve must be installed without fail VED... Vaillant electric instantaneous heater to ensure protection against scalding. Kol1-P Solar circuit pump 1 Kol1 Collector sensor 1 Cylinder sensor 1...
  • Page 23 Electrical installation 5 230V Netz Kol1-P Kol2-P / ZP LEG/BYP LP/UV 1 VRS 560 C1/C2 Kol1 Ertrag Kol2 Fig. 5.6 Connection diagram for hydraulic plan 1: Integration of auroMATIC 560 in monovalent systems Danger! Danger of overheating! When integrating the controller, always install a thermostatic mixer valve to limit the maxi- mum temperature to prevent scalding and pro- tect the unit.
  • Page 24: Hydraulic Plan 2

    5 Electrical installation Hydraulic plan 2 VRS 560 C1/C2 C1/C2 C1/C2 C1/C2 Kol2 Kol1 (VR 11) (VR 11) 230 V LEG/BYP 230 V ~ Kol1-P Kol2-P (VR 10) Ertrag LEG/BYP (VR 10) (VR 10) Fig. 5.7 Hydraulic plan 2 with system configuration: Two col- lector fields, one solar cylinder, connection option for various heaters for reheating the cylinder Designation in...
  • Page 25 Electrical installation 5 VC / VK 230V Netz Kol1-P Kol2-P / ZP LEG/BYP LP/UV 1 VRS 560 C1/C2 Kol1 Ertrag Kol2 Fig. 5.8 Connection diagram for hydraulic plan 2 Note LEG/BYP can be used as a legionella protection pump or an electric heater cartridge. Only one of these options can be used.
  • Page 26 5 Electrical installation Hydraulic plan 2: Connection of a second cylinder or swimming pool VRS 560 C1/C2 Kol1 (VR 11) Kol2 (VR 11) 230 V ~ Kol1-P Kol2-P (VR 10) Ertrag LEG/BYP (VR 10) LP/UV 1 (VR 10) Sp 3 (VR 10) 400 V Fig.
  • Page 27 Electrical installation 5 Designation in Components Designation in Components hydraulic plan/ hydraulic plan/ wiring diagram wiring diagram C1/C2 Connections for controlling the heater used for Yield Sensor for measuring yield (optional) reheating the cylinder LEG/BYP Legionella protection pump or electric heater cartridge Boiler Cylinder sensor 1...
  • Page 28: Hydraulic Plan 3

    5 Electrical installation Hydraulic plan 3 VRS 560 C1/C2 C1/C2 C1/C2 C1/C2 230 V ~ Kol1 (VR 11) 230 V 230 V ~ Kol2 Kol1-P (VR 10) Ertrag LEG/BYP (VR 10) (VR 10) Fig. 5.11 Hydraulic plan 3 with system configuration: One col- lector field, one solid-fuel boiler, one solar cylinder, connection option for various heaters for reheating the cylinder...
  • Page 29 Electrical installation 5 VC / VK 230V Netz Kol1-P Kol2-P / ZP LEG/BYP LP/UV 1 VRS 560 C1/C2 Kol1 Ertrag Kol2 Fig. 5.12 Wiring diagram for hydraulic plan 3 Note LEG/BYP can be used as a legionella protection pump or an electric heater cartridge. Only one of these options can be used.
  • Page 30 5 Electrical installation Hydraulic plan 3: Connection of a second cylinder or swimming pool VRS 560 Kol1 (VR 11) 230 V ~ Kol2 Kol2-P Kol1-P (VR 10) Ertrag LEG/BYP (VR 10) LP/UV 1 (VR 10) (VR 10) 230 V ~ Fig.
  • Page 31 Electrical installation 5 Designation in Components Designation in Components hydraulic plan/ hydraulic plan/ wiring diagram wiring diagram C1/C2 Connections for controlling the heater used for Yield Sensor for measuring yield (optional) reheating the cylinder LEG/BYP Legionella protection pump or electric heater HZ-K Heating circuit cartridge...
  • Page 32: Start-Up

    6 Start-up Start-up All system parameters can then be called up consecu- tively by clicking the dial. You can specify the required Setting system parameters values by turning the dial. The value set can be saved by Certain system parameters have to be set in order to clicking the dial.
  • Page 33 Start-up 6 Display Turn the dial to adjust Setting range Factory setting Setting the activation difference for 2 – 25 K cylinder 1 (The activation difference should always be 2 K greater than the deactivation difference) Setting the deactivation difference for cylin- 1 –...
  • Page 34 6 Start-up Display Turn the dial to adjust Setting range Factory setting PROT OFF, 110 °C – 150 °C 130 °C Solar circuit protection function KOLT: 1, 2 Collector type 1 = flat collector 2 = tube collector OFF, 1, 2, 3, 4, 5, 6, 7, 1 – 7 Anti-legionella function 1 = Monday 2 = Tuesday...
  • Page 35: Resetting The System Parameters To The Default Setting

    Start-up 6 Service/diagnostics 7 Resetting the system parameters to the de- fault setting You can restore the default settings for system parame- ters and timer programs by pressing the programming button "P" for roughly ten seconds. Then the display flashes three times and all of the parameters are reset to the factory defaults.
  • Page 36 7 Service/diagnostics Display Actuators/sensor values Test procedure Cylinder temperature display for cylinder sensor 1 Cylinder temperature display for cylinder sensor 2 Temperature display for cylinder sensor 3 Temperature display for collector sensor 1 Temperature display for collector sensor 2 Temperature display for return flow (yield sensor) Table 7.1 Actuators and sensors (continued) You can check the visual display by clicking on the dial With another click, the current version of the control-...
  • Page 37: Emergency Mode 8

    Emergency mode 8 Technical data 9 Emergency mode When the auroMATIC 560 detects an error, its basic dis- play always shows the error. If either the solar yield or reheating function is possible, the controller carries out this function in spite of the error. Technical data Features Units...
  • Page 38: Sensor Characteristics

    VR 10 standard sensor, type NTC 2.7 K To ensure regular servicing, it is strongly recommended that arrangements are made for a Maintenance Sensor values Resistance value Agreement. Please contact Vaillant Service Solutions (0870 6060 777) for further details. 0 °C 9191 Ohm 5 °C 7064 Ohm 10 °C...