2 Description of the appliance

2
Description of the appliance
2.1

Design

14
13
12
11
10
9
Fig. 2.1
Functional elements of ecoTEC exclusive
Key to Fig. 4.2
1
Expansion vessel
2 Air intake pipe
3 Burner assembly
4 Ignition electrode
5 Gas Valve
6 Diverter valve
7 Hot water heat exchanger
2.2

CE label

CE labelling shows that the appliances comply with
the basic requirements of the following directives:
– Directive 90/396/EEC of the Commission with revisions
"Directive for Harmonisation of Legal Regulations
of the Member States for Gas Consumer UNits" (Gas
equipment directive)
– Directive 92/42 EEC of the Commission with revisions
"Directive Concerning the Efficiency of New Hot Water
Heating Boilers Fired by Liquid or Gaseous Fuels"
(Efficiency directive)
– Directive 73/23/EEC of the Commission with revisions
"Directive Concerning Electrical Operating Equipment
for Use Within Specific Voltage Limits" (Low voltage
directive)
4
– Directive 89/336/EEC of the Commission with revisions
"Directive Concerning Electromagnetic Compatibility"
The units comply with the prototype described in the EU
Prototype Test Approval:
PIN-No.
The units comply with the following standards:
– EN 483
– EN 625
1
– EN 677
– EN 50165
2
– EN 55014
– EN 60335-1
3
– EN 60529
– EN 61000-3-2
– EN 61000-3-3
4
5
6
7
h
8
2.3
8 Aqua-Sensor
9 Electronics box
10 Pump
Table 2.1 Gas council numbers
11 Auto air vent
12 Pressure sensor
2.4
13 Heat exchanger
The Vaillant ecoTEC exclusive is a state-of-the-art appli-
14 Air / flue gas duct
ance which has been constructed in accordance with
recognised safety regulations. Nevertheless, danger to
the life and limb of the user or third parties can still
occur or the appliance or other material assets be im-
paired in the event of improper use.
The unit is intended as a heat producer for closed hot-water
central heating installations in households. Any other use or
extended use is considered to be improper. The manufac-
turer or supplier is not liable for any resulting damage. The
user alone bears the risk. Intended use includes the observ-
ance of the operating and installation manual and the ad-
herence to the inspection and maintenance conditions.
2.5
The identification plate the Valliant ecoTEC exclusive is
attached at the factory to the bottom of the appliance.
CE-0085BR0308
Vaillant Ltd. supports the Benchmark Initiative.
You will find the Benchmark Logbook on the
last page of this instruction manual. It is very
important that this document be filled out
properly when installing, commissioning and
handing-over to the operator of the installation.

Gas council numbers

Appliance
ecoTEC exclusive 832
ecoTEC exclusive 838

Intended use

Identification plate

ecoTEC exclusive installation and maintenance instructions
Gas council numbers
47 044 37
47 044 38

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ecotec exclusive 832Ecotec exclusive 838