SERVICING

LEVELING AND INSTALLATION REQUIREMENTS

It is extremely important that the unit is level. If it is not
level, the ice mold will not fill evenly. This can cause a
reduction in ice rate, uneven sized cubes or water spilling
into the storage area which will cause the ice in the bin to
melt prematurely. See Figure A.
Remember the floor surrounding a drain has a tendency to
slope towards the drain.
Leveling the Unit
1. Use a level to check the icemaker from front to back and from side to side. See Figure B. Use a level to
check the levelness of the icemaker from front to back and from side to side by placing a level on the
inside edge and along the door seal edge for built-in installation. See Figure B.
FRONT
2. If the icemaker is not level, adjust the feet on the
corners of the unit as necessary. See Figure C.
3. Check after each adjustment and repeat the previous
steps as necessary until the unit is level.
Installation Requirements
• The unit may be built into a cabinet. There is no minimum clearance requirement for the top, left or
right sides of the unit.
• The location must allow enough clearance for water, drain, and electrical connections in the rear of
the unit.
• The location must not obstruct air flow to the front of the unit.
SIDE
CLRCO006
Figure B
RAISE
10
Design Features Performance
Figure A
CLRCO029
LOWER
DWR005
Figure C
UL307