Indoor
unit
installation
Installation
plate drilling
and assembly
150mm
or more to ceiling
Indoor unit outline
Installationplate
f" . ....
i
120mm
or more
i
_
o
to wall
'
_
oJ
Right refrigerant
_"
"...................
"_ ....................
pipe hole:
a 65
120ram or more
to wall
Right refrigerant
pipe hole
G 65
A:780(Modelos<
16000
Btu/h),
920(Modelos>f
16000
Btu/h)
Fixing the installation
plate:
1. Fit the installation
plate horizontally
on structural
parts of the walt with
spaces around the installation
plate.
2. If the wal! is made of brick,
concrete
or the like, drill eight (8)
5mm diameter
holes in the wall.
Insert Clip anchor for appropriate
mounting screws.
3. Fit the installation
plate on the wall
with eight (8) type "A" screws..
Fit the Installation Plate and drill holes in
the wall according to the wall structure
and corresponding
mounting points on
the installation plate. (Dimensions are in
"mm" unless otherwise stated)
Placa
de instalaci6n
©
®
®
Drill a hole in the wall
1. Determine hole positions
according
to the diagram detailed
in figure
beside. Drill one (!) hole (65mm)
slanting
slightly to outdoor side.
2. Always use wal! hole conduit when
drilling metal grid, metal plate or
the like..
Wall
Indoorunit
]
_
I Outd°°r unit l
Connective
pipe and drainage
installation
Drainage
1. Run the drain hose sloping
downward.
Do not install the drain
hose as illustrated
beside.
2. When connection
extension
drain
hose, insulate the connecting
part
of extension
drain hose with a
shield pipe.
Connection
pipe
1. For the left-hand
and right-hand
piping, remove the rear plate
bushing from the left side of the
rear plate.
Explain to clients that the pipe
cover must be kept as it may be
used when relocate the air
conditioner
to any other place.
2. For the left-hand
and rearqeft-hand
piping, install the piping as shown.
Bend the connective
pipe to be
laid at 43mm height or less from
the wall.
_Do
not block
r//i
Do not block
water
flow
_1
water
flow
Do not put the end of
hose into water.
Piper
Pipe holder
Pipe
cover
(right)
Cover
(left)
_
Left back
ping
Right
piping
_
Right
back
piping
Indoor
unit outline
\
i
i
i
Connective
pipe
\
,
VE
,
E
I
co
Fastening the indoor unit
Pass the drain hose through the hole
in the wall and connect the indoor unit
to the installation
plate, pressing the
indoor part of the installation
plate
hooks.
Superior
hook
\
hook