Installation
Choosing
the installation
site
Precautions
for installation
Installation
at the following
sites may cause problems.
If you must inevitably
install the unit at one of these sites, please consult your local distributor
beforehand:
1. Site with machine oil.
2.
Sites with a high concentration
of salinity, such as coastal areas.
3.
Sites with sulfuric gas, such as hot water springs.
4.
Sites with high frequency
equipment,
such as wireless equipment,
welding
machines and medical installations.
5.
Sites with flammable
gases or volatile material.
6.
Sites with special environmental
conditions.
7.
Laundry rooms.
indoor
unit
1. The unit must be installed at a site
that does not obstruct the flow of
air.
2. The site must support the weight of
the indoor unit.
3. The site must be easily accessible
for maintenance
and replacement
of the air filter.
4. The site must allow for the
necessary
space around the
indoor unit, as shown in the
following figure.
5. There should be at least 1 meter (3
feet) between the unit and radio
and television devices.
It is ideal
that the unit be installed
at the
center of the environment.
6. It must be far from fire, smoke or
flammable
gases.
7. The indoor unit must be at least
2.3 meters (7.5 feet) from the
ground.
8. The site must allow for the easy
removal of the connector
pipe and
drain hose.
9. The unit must be installed at a site
protected
from direct sunlight.
More
than
12cm
More
than 15cm
More
than 230cm
More
than 12cm
Outdoor
unit
1. The outdoor unit must be installed at a convenient
site that is not exposed
to strong winds. The site should be dry and well ventilated.
2. The site must support the weight of the outdoor unit and allow for vertical
installation.
3. There must not be the possibility of increased
noise and vibration at the
site.
4. The unit must be installed at a site where the noise produced
by its
operation
and air discharge does not disturb the neighbors
or animals.
5. The site cannot have any leakage of flammable
gases.
6. The site must allow for a piping extension of no less than 5 meters (16 feet)
and for pipes measuring
at least 10 meters (33 feet) in length.
7. The site must provide enough space around the unit, as shown in the
diagram.
8. Children must not be able to access the installation
site.
More
than 10cm
More
than 60cm
More
More
than 60cm