Installation - Wells HRCP-Series Operation Manual

Drop-in hot and cold pans
Table of Contents

Advertisement

UNPACKING & INSPECTION
Carefully remove the appliance from the carton. Remove all
protective plastic film, packing materials and accessories from the
Appliance before connecting electrical power or otherwise performing
any installation procedure.
Carefully read all instructions in this manual and the Installation
Instruction Sheet packed with the appliance before starting any

installation.

Read and understand all labels and diagrams attached to the
appliance.
Carefully account for all components and accessories before
discarding packing materials. Store all accessories in a convenient
place for later use.
COMPONENTS
2 ea.
PAN RAIL, SIDE
2 ea.
PAN RAILS, END
1 - 5 ea.
PAN RAILS, INTERMEDIATE ( qty differs with unit)
1 ea.
BACKFLOW PREVENTER ASSEMBLY
1 ea.
DRAIN VALVE
1 ea.
DRAIN SCREEN
PREPARATION
Cutout dimensions for tank units and control panels are listed on the
Installation Instructions provided with the unit.
Countertop must be flat and level before the unit is installed.
cutout is made, add stiffeners or bottom braces to counter as required
to support unit weight.
Provide louvered grills and service access below control panel.
Verify that provided sealants are applied to the underside of the top
flange prior to setting the unit into the cutout.
After installation, apply a thin bead of food-grade silicone sealant
around the flange to seal it to the counter.
IMPORTANT:
Unit flange must be sealed to the counter top. Damage caused by
leaks due to improper installation is NOT covered by warranty.
For installation in plastic (e.g. Corian®) counter tops, the counter
material must be protected from the heat of the warmer in order to
prevent discoloration and/or deterioration. The installer should contact
the manufacturer or distributor of the countertop material for specific
installation instructions.
Avoid storing flammable or combustible materials in, on or near the
appliance.
NOTE: DO NOT discard
the carton or other packing
materials until you have
inspected the appliance for
hidden damage and tested it
for proper operation.
Refer to SHIPPING DAMAGE
CLAIM PROCEDURE on the
inside front cover of this
manual.
Installation procedures must
be performed by a qualified
technician with full knowledge
of all applicable electrical and
plumbing codes. Failure can
result in personal injury and
property damage.
IMPORTANT:
Unit must remain in an upright
position during installation to
prevent damage to the
refrigeration system.
IMPORTANT:
After
Refrigeration system is air
cooled. Recommend louvered
grills or equivalent openings
on left and right side of
condensing unit, with a
minimum size of twice the
condenser area (each
opening) in order to provide
adequate air circulation.
IMPORTANT:
DO NOT block air openings.
Damage to the compressor
will result. Damage caused by
improper air circulation is NOT
covered by warranty.
IMPORTANT:
Access is required for the
operation of the drain valve
and for maintenance of the
refrigeration unit. Provide
adequate access to the drain
valve and refrigeration unit.
5
INSTALLATION
WARNING:
RISK OF
INJURY