Download Print this page

Wells HRCP-7200 Installation Instructions

Self-contained drop-in hot and cold pan
Hide thumbs Also See for HRCP-7200:

Advertisement

Quick Links

INSTALLATION INSTRUCTIONS
SELF-CONTAINED DROP-IN
HOT AND COLD PAN
MODEL HRCP-7200 THRU 7600
MEETS NSF STANDARD 7
PERFORMANCE REQUIREMENTS
AT 3" PAN RAIL DEPTH
R
R
LISTED
STD. 7
MODEL HRCP-7300 SHOWN
5/16
(8)
3
(76)
1/4"NPT
WATER LINE
CONNECTION
1 1/8" DIA. CONDUIT
K.O. TERMINAL
BLOCK CONNECTION
DIMENSIONS (INCHES/MM)
MODE
INCHES
32 3/4
HRCP-7200
46 1/2
HRCP-7300
HRCP-7400
60 1/4
HRCP-7500
74
87 3/4
HRCP-7600
ELECTRICAL
MODEL
VOLTS
208
HRCP-7200
240
208
HRCP-7300
240
208
HRCP-7400
240
208
HRCP-7500
240
208
HRCP-7600
240
WELLS MANUFACTURING COMPANY
2 ERIK CIRCLE P.O. BOX 280 * VERDI, NV 89439
1-888-356-5362 * FAX: 1-800-356-5142
PRINTED IN U.S.A. 2003
8 5/8
10 3/8
(219)
(264)
1"NPT DRAIN
A
MM
832
1181
1530
1880
2229
W A R M E R
AMPS 1-PH
KW
L1 - L2
N
1.9
9.0
N.A.
2.5
10.4
N.A.
3.0
14.4
N.A.
4.0
16.7
N.A.
3.8
18.1
N.A.
5.0
20.8
N.A.
6.0
28.9
N.A.
8.0
33.3
N.A.
6.0
28.9
N.A.
8.0
33.3
N.A.
MINIMUM CLEARANCE REQUIRED FROM
UNIT TO THE NEAREST SURFACE.
BACK
SIDE
0
0
(0)
(0)
TOP VIEW
B
A
27 1/8
(689)
19
1
(505)
(25)
24 3/8
(620)
FLOOR
LEVEL
23
(584)
B
INCHES
MM
25 1/2
648
997
39 1/4
1346
53
66 3/4
1695
80 1/2
2045
R E F R I G E R A T I O N
AMPS 1PH
VOLTS
HP
L2 - N
L1
120
1/4
N.A.
5.5
120
1/3
N.A.
7.0
120
1/2
N.A.
7.5
120
3/4
N.A.
15.3
120
3/4
N.A.
15.3
BOTTOM
FRONT
3
NA
(76)
25 7/8
(657)
CUTOUT
3
MINIMUM
(76)
FINAL PLUMBING ASSEMBLY.
FOLLOW INSTRUCTIONS ON PAGE 2
FRONT
ACCESS
REQUIRED
FOR
CONTROLS
CROSS SEC.
SIDE VIEW
C (CUTOUT)
INCHES
800
31 1/2
1149
45 1/4
1499
59
1848
72 3/4
86 1/2
2197
SINGLE PHASE SUPPLY
3-WIRE 120/208-240V
REFRIGERANT
L1-L2 208-240V
TYPE
L2-N 120VAC 60HZ
R-134-A
R-404-A
ALL MODELS
R-404-A
PERMANENTLY
CONNECTED
R-404-A
R-404-A
page 1 304924 (-)
INCHES
(MM)
C
MM

Advertisement

loading

Summary of Contents for Wells HRCP-7200

  • Page 1 INCHES SELF-CONTAINED DROP-IN UNIT TO THE NEAREST SURFACE. (MM) HOT AND COLD PAN BACK SIDE BOTTOM FRONT MODEL HRCP-7200 THRU 7600 (76) MEETS NSF STANDARD 7 25 7/8 PERFORMANCE REQUIREMENTS AT 3" PAN RAIL DEPTH (657) TOP VIEW LISTED STD. 7...
  • Page 2 SELF-CONTAINED DROP-IN HOT AND COLD PAN INCHES (MM) MODELS HRCP-7200 THRU 7600 side to side and front to back before installing the unit. INSTALLATION INSTRUCTIONS 3. Provide support from below to reduce load on countertop. For remote control panel mounting see below.

This manual is also suitable for:

Hrcp-7300Hrcp-7500Hrcp-7400Hrcp-7600