WARRANTY ......................................................................... xi
SPECIFICATIONS ...............................................................
INSTALLATION .................................................................... 5
OPERATION ........................................................................
PARTS & SERVICE ............................................................. 15
Thank You for purchasing this Wells Bloomfield appliance.
Proper installation, professional operation and consistent maintenance of this appliance will ensure that
it gives you the very best performance and a long, economical service life.
This manual contains the information needed to properly install this appliance, and to use and care for
the appliance in a manner which will ensure its optimum performance.
WARMER
MODEL
VOLTS
HRCP-7200
240/208
60Hz
HRCP-7300
240/208
60Hz
HRCP-7400
240/208
60Hz
HRCP-7500
240/208
60Hz
HRCP-7600
240/208
60Hz
NOTE: For equipment and cut-out dimensions, refer to the Installation Instructions provided with each unit.
TABLE OF CONTENTS
INTRODUCTION
ELECTRICAL SPECIFICATIONS
KW
1ø AMPS
HP
2.5/1.9
10.4/9.0
1/4
4.0/3.0
16.7/14.4
1/3
5.0/3.8
20.8/18.1
1/2
8.0/6.0
33.3/28.9
3/4
8.0/6.0
33.3/28.9
3/4
REFRIGERATION
VOLTS
1ø AMPS
120 60Hz
5.5
120 60Hz
7.0
120 60Hz
7.5
120 60Hz
15.3
120 60Hz
15.3
1
1
8
POWER SUPPLY
REFRIGERANT
REQUIREMENT
R-134a
3-wire: L1, L2, N
#10 AWG min. 60ºC
R-404a
3-wire: L1, L2, N
#10 AWG min. 60ºC
R-404a
3-wire: L1, L2, N
#10 AWG min. 60ºC
R-404a
3-wire: L1, L2, N
#8 AWG min. 60ºC
R-404a
3-wire: L1, L2, N
#8 AWG min. 60ºC