8.1
Viewing Information
The following information is also available by pressing the menu
button and selecting 'information' by pressing the Selector Button,
any error is displayed first then : -
1. Room temperature – °C.
2. Boiler temperature – °C.
3. State burner – 1+2 (1=engine, 2= supplementary burner on).
4. Power – Watts.
5. Energy to date – kWh.
6. Head temp actual value (of the Stirling engine) – °C.
7. Room temperature min. - Room Sensor only
8. Room temperature max. - Room Sensor only
9. Hot water temp (setpoint if tank sensor fitted) – °C.
10. State Hot Water.
11. State heating circuit CH1.
12. Telephone customer service.
8.2
Selecting Set time and date
The following information is also available by pressing the menu
button and selecting 'Set time and date' by pressing the Selector
Button.
1. Hours / minutes
2. Day / month
3. Year
8.3
Selecting Operator section
The following information is also available by pressing the menu
button and selecting 'Operator section' by pressing the Selector
Button.
1. Change language
2. Programme lock – Off/On.
8.4
Selecting Time central heating CH1
The following information is also available by pressing the menu
button and selecting 'Time central heating CH1' by pressing the
Selector Button.
1. Select days
2. Mon-Sun,Mon-Fri,Sat-Sun,Mon,Tue,Wed,Thu,Fri,Sat,Sun
3. Select default timings – programmes 1/2/3
4.1st Time ON -- hrs/mins
5.1st Time OFF -- hrs/mins
5. 2nd Time ON -- hrs/mins
6. 2nd Time OFF -- hrs/mins
7. 3rd Time ON -- hrs/mins
8. 3rd Time OFF -- hrs/mins
9. Copy to -
Monday/Tuesday/Wednesday/Thursday/Friday/Saturday/Sunday.
15
© Baxi Heating UK Ltd 2011

8.0 Contents of Other Functions

8.5
Selecting Time hot water
The following information is also available by pressing the menu
button and selecting 'Time hot water' by pressing the Selector
Button.
1. Select days
2. Mon-Sun,Mon-Fri,Sat-Sun,Mon,Tue,Wed,Thu,Fri,Sat,Sun.
3. Select default timings – programmes 1/2/3
4.1st Time ON -- hrs/mins
5.1st Time OFF -- hrs/mins
6. 2nd Time ON -- hrs/mins
7. 2nd Time OFF -- hrs/mins
8. 3rd Time ON -- hrs/mins
9. 3rd Time OFF -- hrs/mins
10. Copy to -
Monday/Tuesday/Wednesday/Thursday/Friday/Saturday/Sunday.
8.6
Selecting Holidays heating CH1
The following information is also available by pressing the menu
button and selecting 'Holidays heating CH1' by pressing the
Selector Button.
1. Start – Day / month
2. End – Day / month
8.7
Selecting Temps / mode CH1
The following information is also available by pressing the menu
button and selecting 'Temps / mode CH1' by pressing the
Selector Button.
1. Operating mode – Off/Timed/Reduced/On
2. Comfort set point -- °C.
3. Reduced set point -- °C.
4. Optimum start control max – mins (0 - 360mins).
8.8
Selecting Temps / mode hot water
The following information is also available by pressing the menu
button and selecting 'Temps / mode hot water' by pressing the
Selector Button.
1. Operating mode - Off / On
2. Hot water temp setpoint – °C.
3. Legionella function – Off / Periodically / Fixed weekday
4. Legionella funct periodically - 1 / 2 / 3 / 4 / 5 / 6 / 7
5. Legionella funct weekday -
Monday/Tuesday/Wednesday/Thursday/Friday/Saturday/Sunday.
6. Legionella funct time -- hrs/mins.
7. Release HW charging – No restrictions / Eng bu only.
8.9
Service/Special operation
1. Time since maintenance - -- months
2. Telephone customer service
8.10
Selecting Diagnostics engine
The following information is also available by pressing the menu
button and selecting 'Diagnostics engine' by pressing the
Selector Button.
1. Power – W
2. Energy to date – kWh
3. Energy since reset - kWh
4. Reset energy counter - no / yes

Hide quick links: