NAME OF PARTS

Fig. 1 Indoor Unit
1 Operating Control Panel (Fig. 2)
2 MANUAL AUTO button
G
When kept on pressing the MANUAL
AUTO button for more than 10 seconds,
the forced cooling operation will start.
G
The forced cooling operation is used at the
time of installation.
Only for authorized service personnel's
use.
G
When the forced cooling operation starts
by any chance, press the START/STOP but-
ton to stop the operation.
3 Indicator (Fig. 3)
4 Remote Control Signal Receiver
5 OPERATION Indicator Lamp (red)
6 TIMER Indicator Lamp (green)
G
If the TIMER indicator lamp flashes when
the timer is operating, it indicates that a
fault has occurred with the timer setting
(See Page 14 Auto Restart).
7 SUPER QUIET Indicator Lamp (green)
8 COIL DRY Indicator Lamp (orange)
9 Intake Grille (Fig. 4)
0 Front Panel
A Air Filter
B Air Flow Direction Louver
C Right-Left Louver
(behind Air Flow Direction Louver)
D Drain Hose
E Air Cleaning Filter
Fig. 5 Outdoor Unit
F Pipe Unit
G Drain port (bottom)
H Intake Port
I Outlet Port
G Refer to the folded out page on the cover.
En-3
06B029_9315255037-01_En
3
Fig. 6 Remote Control Unit
J SLEEP button
K MASTER CONTROL button
L SET TEMP. button (
/
M COIL DRY button
N Signal Transmitter
O TIMER MODE button
P TIMER SET (
/
) button
Q FAN CONTROL button
R START/STOP button
S SET button
T SWING button
U RESET button
V TEST RUN button
G This button is used when installing the
conditioner, and should not be used un-
der normal conditions, as it will cause the
air conditioner's thermostat function to op-
erate incorrectly.
G If this button is pressed during normal op-
eration, the unit will switch to test opera-
tion mode, and the Indoor Unit's OPERA-
TION Indicator Lamp and TIMER Indicator
Lamp will begin to flash simultaneously.
G To stop the test operation mode, press the
START/STOP button to stop the air condi-
tioner.
W CLOCK ADJUST button
X Remote Control Unit Display (Fig. 7)
Y Transmit Indicator
Z Clock Display
[ Operating Mode Display
\ Timer Mode Display
] Fan Speed Display
` Temperature SET Display
a COIL DRY Display
b SLEEP Display
c SWING Display
2006.2.6, 10:52 AM
)