T775A/B/M SERIES 2000 CONTROLLER
SETUP
SENSORS
SENSOR A
Fig. 36. Setup - Sensors - Sensor A Menu.
SETUP
SENSORS
SENSOR A
UNITS
Fig. 37. Setup - Sensors - Sensor A - Units.
SETUP
SENSORS
SENSOR A
CALIBRATE
Fig. 38. Setup - Sensors - Sensor A - Calibrate.
SETUP
SENSORS
SENSOR A
LABEL
Fig. 39. Setup - Sensors - Sensor A - Label.
62-0254–03
2.2.2. SENSOR A
SETUP
SENSORS
SENSOR A
1. From the Sensors menu, highlight SENSOR A.
2. Press the
UNITS
CALIBRATE
LABEL
EXIT
M24502
SETUP
2.2.2.1. UNITS
SENSORS
SENSOR A
UNITS
IMPORTANT
DEG F
DEG C
1. From the Sensor A selections, use the
SELECT
UNITS FOR
SENSOR A
M24503
2. Press the
3. Use the
4. Press the
SETUP
2.2.2.2. CALIBRATE
SENSORS
SENSOR A
Ensure that the wire size calibration value is within the
CALIBRATE
limits. See "Temperature Sensor Calibration" on page 10.
1. From the Sensor A selections, use the
2. Press the
0.0
o
F
3. Use the
ENTER
VALUE TO
CALIBRATE
SENSOR A
M24504
4. Press the
SETUP
2.2.2.3. LABEL
SENSORS
SENSOR A
For a sensor already labeled, the display positions to and
LABEL
highlights that label.
SENSOR A
1. From the Sensor A selections, use the
BOILER A
OUTDOOR A
DUCT A
2. Press the
DISCHRG A
CHILLER A
3. Use the
ROOM A
SELECT
LABEL FOR
4. Use the
SENSOR A
M24505
NOTE: The label names in list order are: Sensor, Boiler,
18
2. SETUP (ADVANCED OPTIONS)
button to display the Sensor A selec-
tions.
(°F or °C)
This is a global change and affects the unit
values for all temperature parameters on all
displays.
The UNITS screen displays only for Sensor A.
buttons to highlight UNITS.
button to display the temperature units.
and
buttons to highlight F or C.
Default: F (Fahrenheit)
button to accept the units and return to
the Sensor A selections.
(the sensor)
buttons to highlight CALIBRATE.
button to display the calibration degree
value.
and
buttons to increase/decrease the
desired calibration degrees.
Default: 0.0
Range: +/-10°F (+/-6°C)
button to accept the value and return to
the Sensor A selections.
(the sensor input)
buttons to highlight LABEL.
button to display the label list.
and
buttons to scroll through list and
highlight the desired label.
You may need to scroll up or down to view all possi-
ble labels.
button to accept the highlighted label
and exit the list.
Outdoor, Duct, Dischrg, Chiller, Room, Supply,
Return, and Animals.