Section 3: System Administration; Quick Arm; Quick Exit; Auto Arm Control - DSC MAXSYS PC4010 Instruction Manual

V3.0
Hide thumbs Also See for MAXSYS PC4010:
Table of Contents

Advertisement

Section 3: System Administration

3.1 Quick Arm

Keypad Command: [*][6][Access Code]
This option will allow the system to be armed by entering [*] [0] at any
keypad instead of entering an access code. This option must be enabled
in order for the Stay or Away function keys to work. To turn this feature
on, perform the following:
1. Press [*] [6], then enter a valid access code which has the "System
Master" or "Supervisor" option enabled. The display "System
Functions Menu" should appear.
2. Use the arrow keys (< >) to scroll to the message "Quick Arm." Press
[*].
3. To enable or disable quick arming, press the [*] key to select [Y]es or
[N]o.

3.2 Quick Exit

Keypad Command: [*][6][Access Code]
This option will allow a user to exit an armed system through a designated
entry/exit point by entering [*] [0] at a keypad. The system gives the user
2 minutes to exit the premises. Once the user has exited the premises, the
system will continue to be armed. This option must also be enabled in
order for the Exit function key to work.
1. Press [*] [6], then enter a valid access code which has the "System
Master" or "Supervisor" option enabled. The display "System
Functions Menu" should appear.
2. Use the arrow keys (< >) to scroll to the message "Quick Exit." Press
[*].
3. To enable or disable Quick Exit, press the [*] key to select [Y]es or
[N]o.

3.3 Auto Arm Control

Daily Auto Arming
Keypad Command: [*][6][Access Code]
This option will allow the system to be automatically armed at the same
time each day. Auto arming can occur at the same time every day. In order
for this function to work, you must enable the Auto Arm function and
program the Auto-Arm Time (follow the steps below).
To enable auto arming at the same time each day, perform the following:
1. Press [*] [6], then enter a valid access code which has the "System
Master" or "Supervisor" option enabled. The display "System
Functions Menu" should appear.
16