Download Print this page

Viking E-30 Technical Practice page 4

Handsfree speaker phone with dialer
Hide thumbs Also See for E-30:

Advertisement

Setting C - Silence Time Out
This feature selects the length of time that calls will remain connected without voice activity.
Programmable in increments of 10 seconds up to a maximum of 90 seconds (Touch Tones
1 - 9). To disable the silence time out, program 0 in this location. Use chart at the right.
* Note: The factory default is 40 seconds.
Setting D - Dial Next Number on Ring No Answer
If enabled and a ring-no-answer is detected, the E-30
phone will dial the next programmed speed dial num-
ber, and continue to cycle through the emergency
numbers until a call is completed. * Note: This feature is disabled in the factory default.
Setting E - Dial Next Number on Busy
If enabled and a busy is detected, the E-30 phone will dial the next programmed
speed dial number, and continue to cycle through the emergency numbers until a
call is completed. * Notes: This feature is disabled in the factory default setting. If
the busy signal is interrupted with a promotional message, contact your central
office to have it removed.
Setting F - Pulse Dialing Rate (Pulses per Second)
The E-30 phone is capable of different pulse dialing speeds. * Note: The factory
default setting is 10pps (pulses per second).
F. DIP Switch Programming/Speaker and Microphone Adjustments
Two POTs are provided to increase or decrease speaker volume and microphone sensitivity. In certain noisy locations
the microphone sensitivity may need to be decreased as shown below. Caution: Setting the microphone gain too high
may cause distorted audio, prevent the distant party from breaking over and inhibit second number redialing.
Speaker
Volume
G. Programming Examples
To Program the E-30 Phone...
...to store 123456 as the security code
...to store a Touch Tone 9, a four second pause and then a pulse
dialed 333-4444 in the first speed dial position
...to store 555-1234 in the second speed dial position
O
p
e
r
a
t
i
o
n
O
p
e
r
a
t
i
o
n
When the "Call" button is pressed, the E-30 phone goes off-hook, and dials a pre-programmed telephone number. The front
panel LED will light any time the phone is off hook. In the event that the line is busy or there is a ring-no answer, the unit
can be programmed to call additional phone numbers. The phone then cycles through up to 5 pre-programmed speed dial
numbers until the call is answered. The E-30 will hang up on CPC, silence, busy signal, return to dial tone, time out or Touch
Tone command (
#). If programmed to auto-answer, the E-30 will also answer any incoming call.
P
r
o
d
u
c
t
S
u
p
p
o
r
P
r
o
d
u
c
t
S
u
p
p
o
r
Due to the dynamic nature of the product design, the information contained in this document is subject to change without notice. Viking Electronics, and its affiliates and/or
subsidiaries assume no responsibility for errors and omissions contained in this information. Revisions of this document or new editions of it may be issued to incorporate
such changes.
Fax Back Doc 212
DIP Switches
(DIP Switches shown
in factory setting)
t
L
i
n
e
.
.
.
7
1
5
.
3
8
6
t
L
i
n
e
.
.
.
7
1
5
.
3
8
6
Touch Tone
1 or 0
2, 3, 4...9
DIP
Switch
1
Microphone
1
Sensitivity
2
2
3
1
2
3
3
Off
On
Enter Programming
Enter Programming
Enter Programming
.
8
6
6
6
.
8
6
6
6
Printed in the U.S.A.
Setting D
Disabled*
Dials second number after
2, 3, 4...9 rings respectively
Touch Tone
Touch Tone
Position
Description
ON
"Call" button alternately connects and
disconnects calls (factory setting)
OFF
"Call" button connects calls only
ON
Incoming calls answered (factory setting)
OFF
Incoming calls are not answered
ON
Normal operation mode (factory setting)
OFF
Learn mode - Any incoming calls are auto-
matically entered into the programming
mode (no security code required). Use
this option if you have forgotten your
security code.
Step 1 -
Step 2 - Enter Digits:
See Section A
9
F
a
x
B
a
c
k
L
i
n
e
.
.
F
a
x
B
a
c
k
L
i
n
e
.
.
Touch
Silence
Tone
Time Out
0
Disabled
1
10 sec
2
20 sec
3
30 sec
4
40 sec*
5
50 sec
6
60 sec
7
70 sec
8
80 sec
9
90 sec
Setting E
1
Disabled*
2
Enabled
Setting F
1
10 pps*
2
20 pps
1 2 3 4 5 6 # 1 9
7
6 3 3 3 4 4 4 4 # 0 0
5 5 5 1 2 3 4 # 0 1
.
7
1
5
.
3
8
6
.
4
3
4
5
.
7
1
5
.
3
8
6
.
4
3
4
5

Advertisement

loading

This manual is also suitable for: