Viessmann Flue gas system Installation Instructions Manual page 24

Flue gas system for vitocrossal (type cu3), vitodens and vitoladens
Table of Contents

Advertisement

Vertical outlet for sloping or flat roofs
When several roof outlets are installed side
by side, maintain a minimum clearance of 1.5
m between pipes and between flue terminals
and other structural elements. Observe the
clearance of the flue outlet above the roof
(see fig.). If the rated output is ≥50 kW, an
above roof extension is required (see page
28).
Ventilation air
A
Flue gas
B
Rated output
kW
a (min.)
mm
Boiler flue connection
1
Balanced flue roof outlet
2
Pipe outlets for Klöber roof tiles (order
3
the corresponding Klöber tile on site)
or
Universal roof tile
or
Flat roof collar
Balanced flue inspection piece,
4
straight (optional)
Balanced flue sliding coupling
5
(optional)
Balanced flue bend
87° or 2 x 45°
Balanced flue pipe
1 m long
0.5 m long
Fixing clamp
≤ 50
≥50
400
1 000
23