Vitodens 100-W
Flue applications
Vitodens boilers can be installed in
virtually all domestic applications, some
examples are illustrated.
The maximum flue length is the single
biggest consideration.
Maximum flue lengths are provided and have
already allowed for 2 bends of 87° (including
support bends).
For each additional 90° elbow reduce the
maximum flue length by 1 m, each additional
45° elbow by 0.5 m.
For concentric or balanced flue systems
the max. flue length can be up to 19 m. To
match the boiler output to the flue system
length, a concentric factor has to be set - see
installation instructions.
Vertical outlet for sloping or flat roofs
1
Part no.
1
Boiler flue connection
2
Balanced flue roof outlet
Black
Terracotta
3
Universal roof tile
Lead Free Flashing Black
Lead Free Flashing Terracotta
or Flat roof collar
4
Balanced flue inspection
piece, straight (optional)
5
Balanced flue sliding coupling (optional)
Balanced flue bend
87°
2 x 45°
Balanced flue pipe
1 m long
0.5 m long
Fixing clamp
Horizontal wall terminal
3
Part no.
1
Boiler flue connection
2
Balanced flue external wall connection
(incl. wall bezels)
3
Protective grille
4
Balanced flue extension pipe
1 m long
0.5 m long
5
Balanced flue bend
87°
2 x 45°
Fixing clamp
Horizontal flue terminal kit
Flue terminal 1 m, 2 x wall seals,
balanced flue bend
87°
Flue applications
5
60/100
7373230
7373271
7373231
7373272
7452499
7452501
7452500
7452502
7248017
7248017
7373228
7199781
7373236
7194329
7373226
7194323
7373227
7194324
7373224
7194321
7373223
7194320
7176762
7176664
60/100
7441467
7435862
7189821
7189821
7373224
7194321
7373223
7194320
7373226
7194323
7373227
7194324
7176762
7176664
Z009350
1
2
6
4
80/125
A Ventilation air
B Flue gas
C (min.) 400 mm
80/125
Vertical, concentric roof
1
terminal – flat and pitched
Communal flue system –
2
open flued
Horizontal concentric
3
Communal room
4
sealed chimney
Vertical outside wall
5
system
Chimney flue (open flued/
6
balance) with flexible duct
3
3
A Combustion air
B Flue gas