Viessmann Vitodens 100-W Specifications page 15

Gas fired condensing combination and system boiler, type wb1c, with modulating matrix cylinder burner and inox-radial heat exchanger for open flue and balanced flue operation. rated output range: 7.4 to 35 kw
Hide thumbs Also See for Vitodens 100-W:
Table of Contents

Advertisement

Model WB1C
Mode
Rated CH Output
At Tf/Tr 50/30 ºC (condensing)
At Tf/Tr 80/60 ºC (non-condensing)
Rated Central Heating Input (net)
Rated Central Heating Input (gross)
Domestic Hot Water Output range
Max. Nat gas rate (CH mode)
Max LPG
Max. Nat gas rate (DHW mode)
Gas Supply pressure
Natural gas
LPG
Max Permissible gas supply Pressure
Natural gas
LPG
Efficiency/Emissions
Full load 100%
Part load 30%
Seasonal Efficiency (SEDBUK)
SEDBUK rating
NOx classification
DHW/CH
DHW performance @ 35˚C temp. rise
DHW temp. range
Maximum mains water inlet pressure
Min. mains water inlet pressure for max
DHW heat output
Minimum mains water inlet pressure for operation
Minimum DHW flow rate for operation
Minimum CH system pressure - cold
Maximum CH system pressure - hot
Cylinder Capacity
CH flow temp. range
General specification
Integral expansion vessel capacity
Integral expansion vessel pre-charge pressure
Max CH system water content using fitted
expansion vessel, @ 0.75bar and 80˚C
Total water capacity
Lift weight
Total weight (incl packaging)
Electricity supply
Internal fuse
Maximimum power consumption
Water protect. rating
Flue temp. @50/30 - max CH output
Flue temp. @50/30 - min CH output
Flue temp. @80/60 - max CH output
Flue products mas flow rate - NG - max CH output
Flue products mas flow rate - NG - min CH output
Flue products mas flow rate - LPG - max CH output
Flue products mas flow rate - LPG - min CH output
Gas council number
Product ID
Dimens./Connect.
Inner flue duct diameter
Outer flue duct diameter
Boiler dimension H x W x D
DHW outlet & inlet
CH flow & return
Condensate & SV outlet combined
Gas
Max. flue length (BF) horizontal/vertical
* The burner output has to be matched to the flue system, please observe the installation instructions.
System
Unit
19
26
kW
6.5 - 19
6.5 - 26.0
kW
5.9 - 17.3
5.9 - 23.7
kW
6.1 - 17.8
6.1 - 24.3
kW
7.7 - 19.8
7.7 - 27.0
kW
-
-
m3/h
1.9
2.6
kg/H
1.4
1.9
-
-
20
20
37
37
25
25
45
45
%
88.2
88.3
%
97.9
97.9
%
90.3
90.3
A
A
class
5 (<39
5 (<39
mg/kWh)
mg/kWh)
l/min
-
-
˚C
-
-
bar
-
-
bar
-
-
bar
-
-
l/min
-
-
bar
0.5
0.5
bar
3
3
l
-
-
˚C
30-80
30-80
ltr
8
8
bar
0.75
0.75
ltr
125
125
ltr
2.8
2.8
kg
35
36
kg
37
38
230v 50 HZ
230v 50 HZ
A
2.5
2.5
W
102
107
IP X4D
IP X4D
ºC
45
45
ºC
35
35
ºC
68
68
kg/h
30.1
41.1
kg/h
14.6
14.6
kg/h
34
46.4
kg/h
15.9
15.9
41-819-26
41-819-27
CE-0085
CE-0085
BT0029
BT0029
mm
60
60
mm
100
100
mm
700 x 400
700 x 400
x 350
x 350
mm
22
22
mm
22
22
mm
22
22
mm
22
22
m
19
13.5
30
35
26
8.8 - 30.0
8.8 - 35.1
6.5 - 26.0
8.0 - 26.6
8.0 - 31.1
5.9 - 23.7
8.2 - 27.9
8.2 - 32.8
6.1 - 24.3
9.1 - 30.9
9.1 - 36.4
7.7 - 27.0
-
-
6.7 - 26.0
3
3.5
2.6
2.2
2.6
1.9
-
-
2.9
20
20
20
37
37
37
25
25
25
45
45
45
88.3
88.2
88.3
97.5
98.5
97.9
90.4
90.3
90.2
A
A
A
5 (<39
5 (<39
5 (<39
mg/kWh)
mg/kWh)
mg/kWh)
10.6
-
-
30-60
-
-
10
-
-
1
-
-
0.5
-
-
0.5
-
-
0.5
0.5
0.5
3
3
3
-
-
-
30-80
30-80
30-80
8
8
8
0.75
0.75
0.75
125
125
125
3.4
3.4
2.8
37
37
36
39
39
38
230v 50 HZ
230v 50 HZ
230v 50 HZ
2.5
2.5
2.5
106
154
119
IP X4D
IP X4D
IP X4D
45
45
45
35
35
35
68
70
68
49.0
56.9
41.1
17.6
17.6
1.6
54.0
62
46.4
19.4
19.4
15.9
41-819-28
41-819-29
47-819-20
CE-0085
CE-0085
CE-0085
BT0029
BT0029
BT0029
60
60
60
100
100
100
700 x 400
700 x 400
700 x 400
x 350
x 350
x 350
22
22
15
22
22
22
22
22
22
22
22
22
13.5
17
13.5
14/15
Combination
30
35
8.8 - 30.0
8.8 - 35.00
8.0 - 26.6
8.0 - 35.0
8.2 - 27.9
8.2 - 32.7
9.1 - 30.9
9.1 - 36.4
8.0 - 30.0
8.0 - 35.0
3
3.5
2.2
2.6
3.3
3.9
20
20
37
37
25
25
45
45
88.3
88.2
97.5
98.5
90.3
90.2
A
A
5 (<39
5 (<39
mg/kWh)
mg/kWh)
12.3
14.3
30-60
30-60
10
10
1
1
0.5
0.5
0.5
0.5
0.5
0.5
3
3
-
-
30-80
30-80
8
8
0.75
0.75
125
125
3.4
3.4
38
38
40
40
230v 50 HZ
230v 50 HZ
2.5
2.5
134
154
IP X4D
IP X4D
45
45
35
35
68
70
49.0
56.9
17.6
17.6
54.0
62
19.4
19.4
41-819-21
41-819-22
CE-0085
CE-0085
BT0029
BT0029
60
60
100
100
700 x 400
700 x 400
x 350
x 350
15
15
22
22
22
22
22
22
13.5
17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vitodens 100-w wb1c

Table of Contents