RS-232C interface

This unit is equipped with an RS-232C port, capable of receiving commands and sending status information. The commands cover all
transport functions, menu functions and power on/standby.
Return status includes timer readouts, type of disc, and transport status. Additional commands are available to enable/disable the unit's
front panel or IR controls.
RS-232C Specifications
·
9-pin D-Sub (Male)
1
5
9
6
Pin
Signal
Description
2
RxD
Receive data
3
TxD
Transmit data
5
GND
Signal grounding

Command

Command structure
·
Example: PLAY command
Byte
1st
2nd
3rd
>
P
L
Y
02h
3Eh
50h
4Ch
59h
Preamble
All command strings for this unit begin with the start byte "02h" and header byte "3Eh".
Operation Code
Each command has a 3-byte operation code, which are listed in the following pages. The operation code for play is simply PLY (upper-
case letters).
Command/Status Byte
This section determines whether the command is telling the unit to do something, or asking for its status. A lowercase "c" (63h) indi-
cates a command while a lowercase "s" (73h) indicates status response.
Parameter Codes
8 bytes are reserved for parameters on the command/status response. When the status information does not fill up all 8 bytes (most
don't), the extra slots are filled with spaces (20h). In the above example, FWD indicates playing forward at normal (1x) speed.
Check Sum
The check sum is calculated from the ">" in the Preamble to the end of the Parameter Codes. The last two digits of the hexadecimal
addition are shown as ASCII in the Check Sum area. In this example, the Check Sum is derived as follows:
3E + 50 + 4C + 59 + 63 + 46 + 57 + 44 + 20 + 20 + 20 + 20 + 20 = 317
The last two digits, "17" are displayed as ASCII in the Check Sum.
End Byte
This marks the end of the string with "03h".

TASCAM DV-D01UT/C
Mode
: Asynchronous
Data rate
: 9600 bps
Command spacing : >25 ms
Note: For correct operation, wait at least 25ms after receiving the reply to a
command from the DV-D01U before sending the next command.
Character length
: 8 bits
Parity bit
: None
Stop bit
: 1 bit
Transfer bit
: LSBit First
Signal flow
DVD player ß External device
DVD player ∑ External device
4th
5th
6th
7th
8th
c
F
W
D
SP
63h
46h
57h
44h
20h
Check Sum Range
9th 10th 11th 12th
SP
SP
SP
SP
1
20h
20h
20h
20h
31h
7
37h
03h