Getting started
10

Hot swapping interface modules

Hot swapping the 10/100 out of band management module

Hot swapping the management module
FortiGate-4000 Installation and Configuration Guide
7
Slide the power supply module into the slot until the lock clicks into place.
8
Turn on the power supply.
9
Replace the locking strip.
Quickly toggle the chassis power supply switch to turn on the power supply module.
Note: If you press the chassis power supply switch for more than four seconds, the entire
FortiGate-4000 unit turns off.
This procedure describes how to hot swap a pass-through interface module or a
switched interface module.
For more information on these modules, see
page 35
and
"Switched interface module" on page 35
1
From the rear panel of the FortiGate-4000 chassis, loosen the two mounting knots that
fasten the pass-through interface module or the switched interface module that you
want to replace. Do not remove the mounting knots.
2
Do one of the following:
For the pass-through interface module, pull it out.
For the switched interface module, turn its power off and then pull it out.
3
Do one of the following:
Insert the new pass-through interface module into the chassis.
Insert the new switched interface module into the chassis, and turn on its power.
4
Tighten the mounting knots on the pass-through interface module or the switched
interface module.
Follow this procedure to hot swap a 10/100 out of band management module on the
rear panel of the FortiGate-4000 chassis.
For more information, see
1
From the rear panel of the FortiGate-4000 chassis, loosen the two mounting knots that
fasten the 10/100 out of band management that you want to replace. Do not remove
the mounting knots.
2
Pull the module out.
3
Insert the new switched interface module into the chassis.
4
Tighten the mounting knots on the module.
Follow this procedure to hot swap a management module on the rear panel of the
FortiGate-4000 chassis.
For more information on these modules, see
1
Power off the management module that you want to replace.
"Pass-through interface module" on
"10/100 out of band management module" on page
"Management module" on page
Hot swapping modules
respectively.
34.
33.
43