^ Feed the flexible ducting through the
telescopic wall pipe and secure it to
the stub on the motor unit fixing
bracket with a hose clip.
^ Secure the bracket to the outside wall
with 3 screws.
^ Compress the flexible ducting from
the inside of the wall and seal the
gap between the ducting and the
wall pipe with jointing compound.
^ Fit the motor unit over the bracket
and secure it in position.
^ Connect the control cable plug
connectors.
^ Use the extension cable supplied to
lengthen the cabling if necessary.
^ If it is still not long enough, please
refer to the notes in "Electrical
connection".