L.1 Technical Data of the ICP Controller
Board Size
PCI Bus
Weight
Temperature Range in Operation
(measured in the enclosure)
Temperature Range not in Opera-
tion
Humidity in Operation
Maximum Altitude in Operation
Power Consumption (5V, 12V)
L.2 Boot Error Messages
Error Message
"Error detected on SIOP x"
"Memory error detected":
Memory errors of the ICP Controller are also indicated acoustically with the audio alarm of
the ICP Controller (3 beeps repeated every 10 seconds).
The following audio alarm sequence indicates that the ICP Controller is tried to be oper-
ated without a DIMM: "beep-beep-short_pause-beep-beep-long_pause-beep-beep-
short_pause-etc.". All ICP Controller require a memory module for operation.
184
Standard PCI long card format or 2/3 hereof
32 Bit / 64 Bit 33MHz, 5 Volt
0,35 kg
O
O
O
10
to 55
C or 50
O
O
-10
to 60
C or 14
20% to 75% not condensing
3000 meter or approximately 10.000 feet
approximately 10 Watt
possible cause, remarks
SCSI cable defective
hard disk connected defective
SIOP x defective
SCSI bus not properly terminated
termination power missing
Memory Module defective
O
to 131
F
O
O
to 140
F