J.4.5 Menu Advanced Setup: Configure Logical Drives
Logical Drives (hierarchy level 2) are installed in this main menu option.
Selecting Configure Logical Drives leads you to the screen shown next.
The F4 key gives you a list of all the hard disks this Logical Drive consists of. If it is a Logical
Drive of the type Disk, it only consists of one single hard disk. If a Logical Drive consists of
more hard disks, it is of the type Chain (concatenation of several hard disks).
F3 loads the media of removable hard disks and F5 turns for some seconds periodically the
hard disks LED on and off.
To configure and setup an new Logical Drive, select Create new Logical Drive. ICPCON dis-
plays a list of free Physical Drives (which are not already part of a Logical drive).
If you select one Physical Drive with SPACE and press ENTER, ICPCON suggests to create a
SINGLE Drive out of this hard disk.