OPERATION OF THE GENERATOR

Bleeding Instructions

1. With the fuel valve in the off position take off the
rubber fuel line off the fuel pump port.
2. Open fuel valve and let rubber fuel line fill up with
diesel fuel. Quickly replace rubber fuel line on the fuel
pump port
3. Follow starting procedure(page7)
If the unit still won't start.
1. Loosen\remove the steel fuel line compression nut
so you can see the top of the fuel pump. (figure #6)
2. With the throttle lever in the run position turn over the
engine. Diesel fuel should squirt out to the top of fuel
pump.
* If no fuel is coming out of pump retry bleeding
procedures, if still no fuel, possible bad fuel pump.
3. Reconnect fuel line and follow starting procedures.
Fuel pumping but unit will not start.
1. Follow the steel fuel line up to the injector
2. Disconnect the fuel line from the injector with a
17mm wrench (figure #7)
3. Remove the fuel injector from head assembly and
inspect it. Make sure injector tip is clean and free from
debris. Invert it. Reconnect metal fuel line. (figure #8)
4. With the throttle lever in the run position turn over the
engine. You should have four ports of fuel spraying from
the injector tip.
5. Re-install injector in to the head assembly
6. Follow starting procedures.
If the fuel injector does not spray (possible bad injector
If the fuel injector is functioning , look under the valve
cover to see if the valves are function properly.
Figure #6
Rubber Fuel Line
7
Fuel Pump Port
Steel Fuel Line
Fuel Pump

Throttle Lever

Valve Cover
Figure #7
Figure #8
Valve Settings
.012-intake
.013-exhaust