Self-Test Data - Honeywell KLN 90B Installation Manual

Gps rnav
Hide thumbs Also See for KLN 90B:
Table of Contents

Advertisement

BENDIX/KING

Self-test Data

The following ASCII format is used for self-test data:
abcdeeeeffffgggghhhhiiiijjjj
where
Bit
Message Description
a0
DB missing or DB Checksum Error
a1
Battery Low : Service required to prevent loss of user data
a2
User data lost
a3
No RCVR data
a4
No RS-232 Data
a5
RS-232 Data Error
a6
RS-232 Output Error
a7
1
b0
Data Loader Error
b1
ARINC 429 Output Fail
b2
EFIS RCVR Failure
b3
RDRG RCVR Failure
b4
Air Data Fail
b5
WPT Annunciator OCD/FAIL
b6
MSG Annunciator OCD/FAIL
b7
1
c0
Approach ACTV OCD/FAIL
c1
Approach ARM OCD/FAIL
c2
NAV SUPER Flag Failure
c3
unused
c4
unused
c5
unused
c6
unused
c7
1
d0
unused
d1
unused
d2
unused
d3
unused
d4
unused
d5
unused
d6
unused
d7
1
eeee
Receiver Error Status Word
ffff
IC designator in case of EEPROM failure
gggg
IC designator in case of CPU failure
Rev 5, April/2003
: 28 bytes
10521I05.TDC
KLN 90B
Page A-7