HOOk-UP anD OPeRaTIOn InSTRUCTIOnS
nOTe
The HTUPS 2700 must be plugged into a properly grounded, three-prong AC power outlet . In addition, Monster recommends
charging the batteries for at least four hours prior to using HTUPS 2700 . To charge or recharge the batteries, simply plug your
HTUPS 2700 into an AC outlet .
STeP 1 Powering Your HTUPS 2700 and Connected equipment
a) For saftey reasons, the HTUPS 2700 ships with the battery disconnected . You must first manually connect the battery .
See p . 11 for instructions .
b) Plug your AV equipment you would like to protect from power loss into the surge-protected, battery backup-supplied outlets .
C) Plug the HTUPS 2700 into a properly grounded AC outlet . Always keep the HTUPS 2700 plugged into a live outlet
to ensure the battery is charged .
The HTUPS 2700 will then perform a self-test function . The "Clean Power On" LED will flash for 8 seconds . After the test
is completed, the Clean Power On, Protection On, Unswitched On, UPS/AVR, Ground OK, and Wiring OK LEDs will illuminate
steadily . The voltage meter will display input AC voltage level, and the battery runtime LED bar will display current battery capacity .
D) Turn on your HTUPS 2700 switched outlets by pressing the Power On button . The Clean Power On, Protection On, Unswitched
On, Ground OK, Switched On, Wiring OK and UPS/AVR On LEDs will illuminate steadily and the voltage meter will display input
AC voltage level and battery runtime LED bar will display current battery capacity, confirming that there is adequate power to the
connected loads .
e) In the event of a utility power failure, you can still operate your HTUPS 2700, even if the unit was turned off during the power
failure . Only the CABLE/SAT and DVR labeled outlets are still powered by battery during a power failure . Under back-up operation,
the HTUPS will beep slowly . When switched to UPS mode, the unit will beep every four seconds, when the there is approximately
25% charge left, it will beep twice every second . You can turn off the beeping by pressing the Alarm On/Off button once .
7