SUBTASK 25-62-10-450-008
I.

Airframe Ground Connections

(1)
Connect the ground wires to the airframe in accordance with the aircraft manufacturer's
written instructions or as described in AC 43.13-1, Chapter 11, § 15. See "Figure 21. Remote
Switch Harness Wiring Diagram", on page 67.
SUBTASK 25-62-10-450-009
J.

Buzzer Connection

(1)
Connect the power wire to the buzzer positive (+) terminal.
(2)
Connect the ground wire to the buzzer negative (–) terminal.
SUBTASK 25-62-10-450-010
K.

Remote Switch Final Installation

(1)
Insert the harness plug into the remote switch receptacle.
(2)
Install the remote switch assembly, referring to SUBTASK 25-62-10-450-002, on page 63.
COBHAM AVIONICS WULFSBERG ELECTRONICS
ABBREVIATED COMPONENT MAINTENANCE MANUAL
C406-1 (453-5002), C406-1HM (453-5003)
25-62-10
Page 71 of 90