Specifications; Environmental And Physical; Table 2. Environmental And Physical Specifications - ACR Electronics Cobham C406-1 Series Abbreviated Component Maintenance Manual

Emergency locator transmitter
Table of Contents

Advertisement

TASK 25-62-10-870-803

3. Specifications

SUBTASK 25-62-10-870-001
A.

Environmental and Physical

(1)
Table 2 lists the environmental and physical specifications of the C406-1 Series ELT.
NOTE:
CRITERIA
Temperature
Mechanical
Automatic Activation
Weight
Dimensions (LxHxW)
Software
COBHAM AVIONICS WULFSBERG ELECTRONICS
ABBREVIATED COMPONENT MAINTENANCE MANUAL
C406-1 (453-5002), C406-1HM (453-5003)
For automatic activation, the higher threshold of 4.5 ft/sec (2.3
accordance with Eurocae ED-62. Use of the higher threshold crash sensor has been
approved by the FAA as a deviation to TSO C126 (FAA Reference #98-130S-108,
February 6, 1998).

Table 2. Environmental and Physical Specifications

PARAMETER
Storage
Operating
Vibration
Shock
Crashworthiness
Humidity
Penetration
Crush
Altitude
C406-1 Series
(Primary G-Switch)
C-406-1HM
(Auxiliary Five G-Switches)
ELT Complete w/Battery Pack,
Mounting Tray, and Covers
ELT Complete w/Battery Pack,
Mounting Tray, and Covers
In accordance with RTCA/DO-178B, Level D
CHARACTERISTIC
-55° C to +85° C
-20° C to +55° C
g
10
, 5 Hz to 2,000 Hz
500
100
95% for 50 hours
55 lbs from 6 in. (25 kg from 15 cm)
1,000 lbs (454 kg)
55,000 ft (16,764 m)
4.5 ±0.5 ft/sec (2.3
4.25 lbs (1.9 kg)
11.63 x 3.90 x 3.76 in.
(295 x 99 x 96 mm)
25-62-10
g
) is specified in
g
for 4 ms
g
for 23 ms
g
)
g
12
Page 33 of 90
APR 06/10

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents