Mitsubishi Electric NM-VS100 Installation And Operation Manual page 23

Video server box
Table of Contents

Advertisement

-JPEG Settings
Sets up the creation condition, screen size, color and name of JPEG file to be sent to
FTP.
Pre event: Creates the JPEG file of chapter 1~5 for 1~2 seconds before the event is
generated.
Post event: Creates the JPEG file of chapter 1~15 for 1~2 seconds after the event is
generated.
Image size: Selects the size of JPEG file to be created among 160X120 and 320X240.
Color: Selects the color or B&W of JPEG file to be created.
Base Name: Write in the basic name of file to be created.
Except for the basic name, It is possible to add supplementary names for discriminating
multiple files.
Additional suffix: Selects one among date, time and the number of sequence created.
None: Do not add supplementary names.
Date Time: Adds the date and time when the file was created behind the basic name.
Sequence: Adds the number in sequence of file creation behind the basic name.
Event Setup
It is possible to select and operate, from Alarm of Alarm OUT and eMail, the Motion
Event occurred from each of the 4 channels & Quad screen and the Event occurred
from Alarm in port 1 to 2.
IN-OUT Mapping
By connecting the Alarm OUT operations to the events occurred from the Alarm IN,
users can send an eMail or text message.
Alarm IN - Alarm IN comes in Motion, Alarm in port 1 and Alarm in port 2.
Alarm OUT
Alarm: Operate the equipment connected to the Alarm OUT port to the events
occurred from the Alarm IN.
eMail: Send an email to events occurred from the Alarm IN.
FTP:
Sends the captured picture to FTP by the event which occurs from Alarm
input.
□Enable mandatory alarm out: Enable alarm control to open/close contact.
- 17 -