Whirlpool COMMERCIAL DRYERS Installation Instructions Manual page 5

Commercial dryers
Hide thumbs Also See for COMMERCIAL DRYERS:
Table of Contents

Advertisement

ELECTRIC
DRYER MODELS
6. If local codes DO NOT permit frame grounding
to the neutral
wire of the power supply cord:
(1)
(2)
(3)
Remove terminal
block cover.
Remove the ground
wire (green)
from the
external
ground connector
and fasten under
center silver colored
terminal
block screw.
Connect the neutral wire of the power supply
cord to the center
silver
colored
terminal
of the terminal
block and connect
the other
wires
to the outer
terminals.
See Fig. 10.
For connecting
plain-end
field
wire
see
Fig. 14.
CONNECT
SEPARATE
COPPER GROUND
WIRE
FROM EXTERNAL
GROUND
CONNECTOR
TO APPROVED
GROUND
',
,'
b-3,
CENTER
SILVER
COLORED
TERMINAL
BLOCK
SCREW
GROUND
WIRE
(GREEN)
CENTER)
COPPER
POWER SUPPLY
CORD
(WITH STRAIN
RELIEF)
-
30 AMPERES)
TO FUSED DISCONNECT
BOX OR APPROVED
WIRING
DEVICE
FOR
POWER SUPPLY
CORD
(4)
(5)
UNGROUNDED
NEUTRAL
FIGURE
10
Connect
a separate
copper
ground
wire
(#lo
minimum)
to a grounded
cold water
pipe' by means of a clamp and then to the
frame
of the appliance
at the external
ground connector.
Use Part #685463 ground
wire and clamp assembly.
Do not ground
to
a gas supply pipe. Do not connect
the power
supply
cord to electric
power
supply
until
appliance
is permanently
grounded.
See
Fig. 11.
Replace terminal
block cover.
EXTERNALGPO"ND
FIGURE
11
*Grounded
cold water
pipe must have metal
continuity
to electrical
ground
and
not
be interrupted
by plastic,
rubber
or electrically
insulating
connectors
(including
water
meter
or pump)
without
adding
a jumper
wire at these connections.
See FIG.
12
FIGURE
12
C. If connecting
to a four-wire
electrical
system
(mobile
home):
(1)
(2)
(3)
(4)
(5)
Remove terminal
block cover.
Remove the ground
wire (green)
from the
external
ground
connector
and fasten under
center silver colored
terminal
block screw.
Connect
the ground
wire
(green)
of the
power supply
cord to the external
ground
connector.
Connect the neutral wire (white) of the power
supply
cord
to the center
silver
colored
terminal
of the terminal
block and connect
the other wires to the outer terminals.
See
Figure 13. For connecting
plain-end
field
wire, see Figure 14.
Replace terminal
block cover.
EXTERNAL
GROUND
CONNECTOR
\
.'J,.,
GREEN WIRE OF HARNESS
GREEN WIRE
NEUTRAL
TO FU"'"
_Ic
JCY "Ia-
(WHITE 0R
CCI Ia_"
CONNtr.
I DVA
CENTER)
FOUR WIRE POWER
- j+.SiJPPLY
CORD (WITH
STRAIN
RELIEF)
(30 AMPERES)
4 WIRE UNGROUNDED
NEUTRAL
FIGURE
13
5