Siemens XT55 AVL User Manual page 29

Cellular engine
Table of Contents

Advertisement

XT55 AVL User's Guide
Confidential/Released
$PSRF112,
Parameter description:
Value,
value:
key_number,
*XX
Example :
$PSRF112,12,2*14
This command displays the settings of given key number (2).
The received format is: $alarm key (2): phone: 012345678, protocol: RMC
$PSRF112,
Parameter description:
value,
value:
interval,
phone_number
*XX
phone_number //set the authorized telephone number
*XX
Example:
$PSRF112,40,2,012345678*07
This command enables the device to periodically send an SMS to the target
number in the case of an alarm. In the given example the SMS will be send every 2
minutes to the example target number (012345678).
$PSRF112,
Parameter description:
value,
value:
*XX
*XX
Example 2:
$PSRF112,41*0C
This command disables the periodical sending of SMS
XT55_avl_ug_V03
// configure the alarm keys
Defined value
12 // displays key number
// configure the sending of SMS
Defined value
40 // enable sending of SMS on interval of time (periodically)
interval // determine the interval of time on which an SMS has to be
delivered (unit is minute)
// CheckSum has to be calculated.
// configure the sending of SMS
Defined value
41 // disable periodically sending of SMS
// CheckSum has to be calculated.
Page 29 of 37